Electrical Specifications
Protections
Main Output
Overcurrent protection2
Overvoltage protection1
Overtemperature protection
Fan fault protection
Standby Output
Over-current protection3:
Over-voltage protection1
MIN
107%
13.5 V
110%
3.6 V
NOM
Yes, autorecovery
Yes
1 Latch mode
2 No shutdown if the overcurrentis within the range and does notlast for more than 200 ms, otherwise latch will occur
3 Autorecovery
MAX
130%
15.0 V
150%
3.9 V
Control and Status Signals
Input Signals
PSON_L
Active LOW signal which enables/disables the main output. Pulling this signal LOW will turn-on the main output.
Recommended pull-up resistor to VSB is 5.1 kohms. A 100 pF decoupling capacitor is also recommended.
MIN
MAX
VIL
VIH
ISOURCE
ISINK
PSKILL_H
Input logic level LOW
Input logic level HIGH
Current that may be sourced by this pin
Current that may be sunk by this pin at low state
2.0 V
0.8 V
3.6 V
2 mA
0.5 mA
First break/last mate active LOW signal which enables/disables the main output. This signal will have to be pulled to ground at the system side with a 220 ohm
resistor. A 100 pF decoupling capacitor is also recommended.
MIN
MAX
VIL
VIH
ISOURCE
ISINK
VSENSE+, VSENSE-
Input logic level LOW
Input logic level HIGH
Current that may be sourced by this pin
Current that may be sunk by this pin at low state
2.0 V
0.8 V
3.6 V
2 mA
0.5 mA
VSENSE+ and VSENSE- lines are the remote sense lines for regulation. Each line will compensate for a maximum of 100 mV
Ordering Information
Model Number
DS1100SLPE-3
DS1100SLPE-3-001
1 Derating may apply.
I2C Addressing
A1 Pin
0
0
1
1
A0 Pin
0
1
0
1
Nominal Main Output
12 V
12 V
PMBus (w/r)
B0/B1
B2/B3
B4/B5
B6/B7
Standby Output
3.3 V @ 3 A
3.3 V @ 3 A
Airflow Direction
Std (forward)
Reverse1