English
Language : 

BXF400 Datasheet, PDF (2/3 Pages) Artesyn Technologies – 264W Wide Input DC/DC Converters
BXF400 Series
Single output
DC/DC CONVERTERS 264W Wide Input DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
264W
INPUT
VOLTAGE
48VDC
OVP
3.8 VDC
INPUT
OUTPUT
OUTPUT CURRENT CURRENT
VOLTAGE (MAX. LOAD) (MAX.)
3.3V
7.0A
80A
EFFICIENCY
(TYP.)
REGULATION
LINE LOAD
78%
±0.10% ±0.15%
MODEL
NUMBER (8)
BXF400-48S3V3LJ
Notes
1 Measured with 10µF tantalum capacitor and 1µF ceramic capacitor across
the output.
2 Iout = Inom; delta Iout = ±25% Iout (max), di/dt = 1A/µs.
3 Input fusing is required based on surge and maximum input current.
4 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5 Input reflected ripple current test set-up uses a Pi filter; 220µF, 12µH,
100µF.
6 Start-up into resistive load.
7 Units should be characterised within systems. External components and
filtering required.
8 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details..
PROTECTION
Short circuit protection
Overvoltage protection
Undervoltage protection
Thermal protection
TELECOM SPECIFICATION
Central office interface A
Continuous, automatic recovery
Latching
Non-latching
110°C baseplate,
automatic recovery
ETS300-132-2
PIN CONNECTIONS
PIN NUMBER
FEATURE
1
Power Good
2
Current Monitor
3
Parallel
4
Trim Adjust
5
+ Sense
6
- Sense
EXTERNAL OUTPUT TRIMMING
Output can be externally
trimmed by using the
method shown.
8
TRIM
UP
7
RT1
OR
RT2
TRIM
DOWN
6
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-0148
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
File Name: bxf400.pdf Rev: 30 Mar 2006