English
Language : 

BXB75-48D3V3-2V5FL Datasheet, PDF (2/3 Pages) Artesyn Technologies – 60-75W Wide Input DC/DC Converters
BXB75 Series
Dual output
DC/DC CONVERTERS 60-75W Wide Input DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
OUTPUT
VOLTAGE
OP1 OP2
OUTPUT
CURRENT
(MIN.) (14)
OUTPUT
CURRENT
(MAX.) (12)
TYPICAL
EFFICIENCY
REGULATION
LINE LOAD
MODEL
NUMBER (7)
60W 36-75VDC 4.0/3.0VDC 3.3V 2.5V
1A
15A
74% (10) ±0.25% ±0.50% BXB75-48D3V3-2V5FL
75W 36-75VDC 6.0/4.0VDC 5V 3.3V
1A
15A
82% (9) ±0.25% ±0.50% BXB75-48D05-3V3FL
Notes
1 Measured with 10µF tantalum capacitor and 0.1µF ceramic capacitor
across output.
2 di/dt = 1A/1µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to 0.75
lo max. and 0.75 lo max. to 0.5 lo max.
3 Units should be characterised within systems. External components
required.
4 Input fusing is recommended based on surge current and maximum input
current.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Simulated source impedance of 12µH.
7 Option with active high remote on/off (standard product is active low) is
available. Designate with the suffix ‘FH’, e.g. BXB75-48D05-3V3FH.
BXB75-48D3V3-2V5FH is not available.
8 Start-up in resistive load.
9 5V at 15A.
10 Measured with 15A load on 3.3V output and 5A load on 2.5V output.
11 Numbers in brackets refer to output 1.
12 Combined maximum output current that may be drawn from both channels
simultaneously is 20A (i.e. current from OP1 + current from OP2).
13 Connect input to case when performing hipot test from output to case.
14 1A minimum load required on the higher voltage output.
PIN CONNECTIONS
PIN
NUMBER
FUNCTION
1
- Vin
2
Case
3
Remote ON/OFF
4
+ Vin
5
OP1 Trim
6
OP1 Return
7
OP1
8
OP2 Trim
9
OP2 Return
10
OP2
PROTECTION
Short circuit protection
5V/3.3V
3.3V/2.5V
Continuous, 25A max.
auto restart
Continuous, 32A max.
auto restart
Input surge protection
100VDC for one second max.
non repetitive
Reverse voltage protection
(See Note 4)
Yes, up to 17A with
source impedance of 5Ω
Overvoltage protection
Latching, 120% Vout
Undervoltage protection
Non-latching
Thermal protection
110°C baseplate, automatic recovery
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2
EXTERNAL OUTPUT TRIMMING (11)
Output can be externally
trimmed by using the
method shown.
9 (6)
TRIM
UP
8 (5)
TRIM
DOWN
RT1
OR RT2
10 (7)
www.artesyn.com
File Name: BXB75D.PDF Rev: 24 Apr 2002