English
Language : 

BXA200 Datasheet, PDF (2/4 Pages) Artesyn Technologies – Single output
DC/DC CONVERTERS | 130-200W DC/DC
130 to 200 Watt
High density DC/DC converters
INPUT OUTPUT OUTPUT OUTPUT
RIPPLE & NOISE STATIC REG.
EFFICIENCY
VOLTAGE POWER VOLTAGE CURRENT
PK-PK, MAX. (1)
BAND (2)
OVP
THRESHOLD
MODEL
NUMBER
38-75VDC 130W
3.3V
40A
78%
60mV
55mV, Max.
4.5 to 5.5VDC BXA200-48S3V3
38-75VDC 200W
5V
40A
83%
100mV
50mV, Max.
6.0 to 7.0VDC BXA200-48S05
38-75VDC 200W
12V
16.7A
83%
110mV
112mV, Max. 14.25 to 15.75VDC BXA200-48S12
38-75VDC 200W
15V
13.3A
83%
100mV
130mV, Max. 17.57 to 19.42VDC BXA200-48S15
38-75VDC 200W
24V
8.3A
84%
150mV
185mV, Max. 27.0 to 29.9VDC BXA200-48S24
38-75VDC 200W
48V
4.16A
85%
250mV
328mV, Max. 65.0 to 72.0VDC BXA200-48S48
Notes
1 A 10µF tantalum capacitor on the output.
2 Specified for all conditions line and load.
3 Fit external 1KΩ resistor in series with remote on/off pin.
4 Normal operation: When a high impedance power source is used, an
aluminium electrolytic capacitor of value 220µF rated at 100V should be
placed across the two voltages input pins, –Vin and +Vin. This capacitor
should be located as close as possible to the input terminals.
5 Remote sense operation: Remote sense will automatically compensate
for output voltage line losses up to 0.5VDC.
The unit will operate if the sense terminals are left open. There are internal
resistors between each sense line and the output terminal. However,
regulation will degrade if the sense lines are left open. Do not reverse the
sense leads as this may damage the unit.
6 External trimming: The modules allow a trim range of ±10% of the output
voltage to the rated maximum power. Trimming is implemented as shown.
7 Synchronization function: This function allows the synchronisation of the
fixed switching frequency to an external clock. The frequency adjustability
range is 500kHz ±35kHz and the synch. function is TTL compatible,
coupled through a 1nF capacitor. Two or more units can be synchronized
to each other by connecting all of the synch. pins together.
8 Parallel and N+I redundancy operation:
Parallelling: Two or more units can be paralleled to give higher power
operation. The power output will be a multiple of the power block. Diodes
are not necessary for parallel operation.
N+I Redundancy: If redundancy is required, isolating diodes should be
used. In this set-up when one unit is turned off, it will disconnect itself from
the sharing group and the other unit(s) will take up the extra load.
9 Thermal performance: The baseplate must be kept below 85°C during
normal operation. This can be achieved by providing the proper amount of
moving air coupled with the proper size heatsink. The thermal impedance
in still air with no heatsink is 5.0°C/W. If the baseplate temperature exceeds
100°C, the thermal protection circuitry protects the module by decreasing
the current limit setpoint.
10 With a 120µF capacitor across the input terminals.
11 Contact your local distributor.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Parallel and N+1 Redundancy Operation (See Note 8)
- Vin
+ Vin
Remote ON/OFF
- Vin
+ Vin
Remote ON/OFF
- Sense
- Vout
- Vout
+Vout
+Vout
+Sense
Trim
Synch.
- Sense
- Vout
- Vout
+Vout
+Vout
+Sense
Trim
Synch.
RL
InF
Synch. Gen
http://www.artesyn.com
PAGE 2