English
Language : 

BXA10-12S05J Datasheet, PDF (2/4 Pages) Artesyn Technologies – Embedded Power for Business-Critical Continuity
Embedded Power for
Business-Critical Continuity
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Rev.03.07.07
bxa10
2 of 4
OUTPUT SPECIFICATIONS
Line regulation
LL to HL, single output
LL to HL, dual output
±0.2%
±0.2%
Load regulation
10% to 100% FL (See Note 4)
±0.5%
Minimum load
48 V models
12 V models
10% full load
No minimum load
Overshoot
At start-up
10% max.
Ripple and noise
(See Note 2)
5 Hz to 20 MHz
100 mV pk-pk, max.
20 mV rms
Transient response
25% load step
±2.0% max. dev.,
250 μs recovery
to within ±1.0%
Temperature coefficient
±0.02%/°C max.
Overvoltage protection Clamp type
See table
Short circuit protection Hiccup
Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
12 Vdc (See Note 6)
48 Vdc
9-18 Vdc
18-75 Vdc
Input filter
Pi type
Start up surge current Resistive load
1.5 A max.
Remote ON/OFF
ON (See Note 3)
OFF
OFF idle current
Open collector compatible
High impedance >400 kΩ
Low impedance <1.0 kΩ
<1.5 mA
Start-up time
1.6 s, max.
EMC CHARACTERISTICS
Conducted emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC (See Note 8)
Level A
EN61000-4-2, level 2
Perf. criteria 1
EN61000-4-2, level 3
Perf. criteria 1
EN61000-4-5, level 2
Perf. criteria 1
EN61000-4-4, level 2
Perf. criteria 1
EN61000-4-3, level 3
Perf. criteria 1
EN61000-4-6, level 3
Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Input/output
Input or output to case
1500 Vdc
1000 Vdc
Switching frequency
Fixed
400 kHz
Approvals and
standards
Safety
VDE0805, EN60950, IEC950
UL1950, CSA C22.2 No. 950
Case material
Black coated, six-sided metal case
Material flammability
UL94V-0
Weight
20 g (0.71 oz)
MTBF
MIL-HDBK-217F
Bellcore
519,000 hours
>2 million hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
-25 °C to +71 °C
(See derating curve)
Non-operating amb. -55 °C to +125 °C
Case
+110 °C max.
Derating
See derating curve
Cooling
Free air convection cooled
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non operating
10,000 feet max.
40,000 feet max.
Vibration
5-500 MHz
2.5 G rms (approx.)