SIL40C2-00SADJ-VJ_15 Datasheet, PDF (1/4 Pages) Artesyn Technologies – C-Class Non-Isolated | |||
|
POWER
Data Sheet
SIL/SMT40C2 Series
C-Class Non-Isolated
Total Power: 40 Amps
Input Voltage: 4.5 - 13.8 Vdc
# of Outputs: Single
SPECIAL FEATURES
ÂÂ 40 A current rating
ÂÂ Input voltage range: 4.5 - 13.8 Vdc
ÂÂ Output voltage: 0.6 - 5 V
ÂÂ Industry-leading value
ÂÂ Cost optimized design
ÂÂ Excellent transient response
ÂÂ Output enable
ÂÂ Output voltage adjustability
ÂÂ Supports silicon voltage migration
ÂÂ Reduced design-in and qual time
ÂÂ RoHS compliant
SAFETY
ÂÂ UL, cUL CAN/CSA 22.2 No.
E139421 UL6950 File No. TBD
ÂÂ TÃV Product Service (EN60950)
ÂÂ Certificate No. TBD
ÂÂ CB report and certificate to
IEC60950
Electrical Specifications
Input
Input voltage raÂnge
Input current
Minimum load
Remote OFF
Input current (max.)
See Note 3
Start-up time
Remote ON/OFF
Output
Output voltage
See Note 5
Output setpoint accuracy
0.1% trim resistors
Line regulation
Low line to high line
Load regulation
Full load to min. load
Min./max. load
Overshoot
At turn-on
Undershoot
At turn-off
Ripple and noise
5 Hz to 20 MHz
See Note 1
Transient response
See Note 1, 2
General
Efficiency (high input)
Switching frequency
Material flammability
Weight
MTBF
Coplanarity
Vin = 5 V, Vo = 2.5 V, lo = 20 A
Fixed
12 V @ 40 °C, 100% load
Bellcore 332
Surface mount models
4.5 - 13.8 Vdc
50 mA
5 mA
25 A @ lo max.
3 ms
0.6 - 5 V
±1.0%
±0.2%
±0.5%
0 A/40 A
0.5% max.
100 mV max.
25 mV
Vin = 5 V, Vout = 2.5 V
130 mV max. deviation 50 μs
recovery to within regulation band
94%
500 kHz
UL94V-0
17 g (0.06 oz.)
6,749,409 hours
150 μm
|
▷ |