English
Language : 

NTS358-CF Datasheet, PDF (1/5 Pages) Artesyn Technologies – 350 Watts
POWER
Data Sheet
Total Power: 200 - 350 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Active power factor correction
ƒƒ IEC EN6100-3-2 compliance
ƒƒ Remote sense
ƒƒ Power fail and remote inhibit
ƒƒ Single wire current sharing
ƒƒ Built-in EMI filter
ƒƒ Low output ripple
ƒƒ 5 V standby
ƒƒ 12 V fan output
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ DC power good
ƒƒ Built in OR-ing diode/FET
ƒƒ Optional fan cover (-CF suffix)
ƒƒ Optional end fan cover (-CEF suffix)
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ CSA
ƒƒ cULus
ƒƒ NEMKO
ƒƒ AUSTEL
ƒƒ CB
ƒƒ CE
ƒƒ CCC
60950
0950
60950
60950 (-CEF)
60950
60950
Certificate and report
Mark (LVD)
Certificate
NTS350 Series
350 Watts
Electrical Specifications
Input
Input ra­nge:
85 - 264 Vac (wide range)
Frequency:
47 - 440 Hz (47- 63 Hz for -CEF versions)
Inrush current:
38 A max., cold start @ 25 °C
Efficiency:
85% typical at full load
EMI filter:
FCC Class B conducted and radiated; CISPR22 Class B conducted
and radiated; EN55022 Class B conducted and radiated;
VDE0878PT3 Class B conducted and radiated.
Safety ground leakage
current:
< 0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
200 W for convection; 350 W with 30CFM forced air
Adjustment range:
± 5%
Standby output:
5 V @ 2 A regulated, ± 5%
Fan output:
12 V @ 1 A, -5 %, +7%, 0.5 A for -CF version
Hold-up time:
20 ms @ 350 W load, 115 Vac nominal line at factory voltage setting
Overload protection:
Short circuit protection on all outputs. Case overload protected @
115 - 130% of peak rating
Overvoltage protection:
20 - 35% above nominal output