English
Language : 

NPT42-M Datasheet, PDF (1/3 Pages) Emerson Network Power – NPT40 Series 45 Watts
POWER
Data Sheet
NPT40-M Series
55 Watts
Total Power: 45 - 55 Watts
Input Voltage: 90 - 264 Vac
120 - 300 Vdc
# of Outputs: Triple
SPECIAL FEATURES
ƒƒ Medical and ITE safety approvals
ƒƒ Universal input
ƒƒ Less than 1U high
ƒƒ 2” x 4” footprint
ƒƒ Overload and short circuit protection
ƒƒ High MTBF
ƒƒ Built in EMI filter (CISPR 22 Class B)
ƒƒ 0 °C to +80 °C operation
ƒƒ Input power < 74 watts
ƒƒ Complies with EN61000-3-2
ƒƒ Class I approved
ƒƒ Class II approved (with Class A EMI)
ƒƒ LPX100 enclosure kit available
ƒƒ Dual AC fuses
ƒƒ RoHS compliant
SAFETY
ƒƒ TUV:
ƒƒ UL:
ƒƒ CSA:
ƒƒ CB:
60950, 60601-1, 3rd edition
60950, 60601-1
60950, 60601-1
Certificate and report
3rd edition
ƒƒ CE:
ƒƒ CQC:
Mark (LVD)
Mark
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac (wide range) 127 - 300 Vdc
Frequency
47 - 440 Hz
Inrush current
< 50 A peak @ 230 Vac, cold start @ 25 °C
Input power
< 74 Watts
Efficiency
75% average
EMI/RFI
FCC Class B conducted; CISPR 22 Class B conducted; EN55022
Class B conducted, VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz; 264 Vac input
Output
Maximum power
45 W for convection
55 W with 30CFM forced air
Hold-up time
10/20 ms 115/230 Vac input line
Overload protection
Short circuit protection on all outputs. Case overload protected @
110% to 160% above peak rating
Overvoltage protection 6.5 to 7.5 Vdc on the main output