NPS62-M Datasheet, PDF (1/3 Pages) Emerson Network Power – 60 Watts | |||
|
POWER
Data Sheet
NPS60-M Series
60 Watts
Total Power: 60 Watts
Input Voltage: 90 - 264 VAC
127 - 300 VDC
# of Outputs: Single
SPECIAL FEATURES
ÂÂ Medical and ITE safety approvals
ÂÂ Universal input
ÂÂ Less than 1U high
ÂÂ 2â x 4â footprint
ÂÂ Remote sense
ÂÂ Overload and short circuit protection
ÂÂ Adjustable output voltage
ÂÂ High efficiency
ÂÂ High MTBF
ÂÂ Built-in EMI filter (CISPR 22 Class B)
ÂÂ International Efficiency Level V,
Energy Star 2.0 & CeC compliant
(except NPS62-M)
ÂÂ Less than 300 mW no-load power
consumption (less than 500 mW for
NPS62-M)
 0 °C to +80 °C operation
ÂÂ Input power < 74 watts
ÂÂ Complies with EN61000-3-2
ÂÂ UL Class I approved
ÂÂ Class II approved (with Class A EMI)
ÂÂ LPX100 enclosure kit available
ÂÂ Dual AC fuses
ÂÂ RoHS compliant
SAFETY
ÂÂ TUV:
ÂÂ UL:
ÂÂ CSA:
ÂÂ NEMKO:
ÂÂ CB:
ÂÂ CE:
ÂÂ CCC:
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate and report
Mark (LVD)
Mark
Electrical Specifications
Input
Input raÂnge
90 - 264 Vac (wide range) 127-300 Vdc
Frequency
47 - 63 Hz
Inrush current
< 50 A peak @ 230 Vac, cold start @ 25° C
Input power
< 74 Watts
Efficiency
87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
EMI/RFI
FCC Class B conducted; CISPR 22 Class B conducted; EN55022
Class B conducted, VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz; 264 Vac input
Output
Maximum power
60 W for convection
Adjustment range
± 20% minimum
Hold-up time
13/75 ms 115/230 Vac input line
Overload protection
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Overvoltage protection 30-50% above nominal output
Remote sense
Compensated for 0.5 V lead drop max. Will operate without remote
sense connected. Reverse connection protected.
|
▷ |