POWER
Data Sheet
NPS60-M Series
60 Watts
Total Power: 60 Watts
Input Voltage: 90 - 264 VAC
127 - 300 VDC
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Medical and ITE safety approvals
ƒƒ Universal input
ƒƒ Less than 1U high
ƒƒ 2” x 4” footprint
ƒƒ Remote sense
ƒƒ Overload and short circuit protection
ƒƒ Adjustable output voltage
ƒƒ High efficiency
ƒƒ High MTBF
ƒƒ Built-in EMI filter (CISPR 22 Class B)
ƒƒ International Efficiency Level V,
Energy Star 2.0 & CeC compliant
(except NPS62-M)
ƒƒ Less than 300 mW no-load power
consumption (less than 500 mW for
NPS62-M)
ƒƒ 0 °C to +80 °C operation
ƒƒ Input power < 74 watts
ƒƒ Complies with EN61000-3-2
ƒƒ UL Class I approved
ƒƒ Class II approved (with Class A EMI)
ƒƒ LPX100 enclosure kit available
ƒƒ Dual AC fuses
ƒƒ RoHS compliant
SAFETY
ƒƒ TUV:
ƒƒ UL:
ƒƒ CSA:
ƒƒ NEMKO:
ƒƒ CB:
ƒƒ CE:
ƒƒ CCC:
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate and report
Mark (LVD)
Mark
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac (wide range) 127-300 Vdc
Frequency
47 - 63 Hz
Inrush current
< 50 A peak @ 230 Vac, cold start @ 25° C
Input power
< 74 Watts
Efficiency
87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
EMI/RFI
FCC Class B conducted; CISPR 22 Class B conducted; EN55022
Class B conducted, VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz; 264 Vac input
Output
Maximum power
60 W for convection
Adjustment range
± 20% minimum
Hold-up time
13/75 ms 115/230 Vac input line
Overload protection
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Overvoltage protection 30-50% above nominal output
Remote sense
Compensated for 0.5 V lead drop max. Will operate without remote
sense connected. Reverse connection protected.