English
Language : 

NLP65-9605GJ Datasheet, PDF (1/5 Pages) Artesyn Technologies – Single, Dual and Triple Output
POWER
Data Sheet
NLP65 Series
Single, Dual and Triple Output
Total Power: 65 - 75 W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc*
# of Outputs: Single, dual, triple
SPECIAL FEATURES
ƒƒ Universal input
ƒƒ 3” x 5” footprint
ƒƒ Low profile fits 1U applications
ƒƒ EN61000-3-2 compliance option (HCC)
ƒƒ Overvoltage and short circuit protection
ƒƒ 65 W with free air convection cooling
ƒƒ EN55022, EN55011 conducted
emissions level B
ƒƒ EN61000-4-2,-3,-4, -5, -6
immunity compliant
ƒƒ RoHS compliant
ƒƒ LPX80 enclosure kit available
ƒƒ Two year warranty
SAFETY
ƒƒ VDE0805/EN60950-1
File No. 1040100-3336-0096
ƒƒ License No. 114404
ƒƒ UL
60950-1
ƒƒ cUL
60950-1
ƒƒ CCC
60950-1
ƒƒ CE
LVD Directive
*NLP65-76xx version only
Electrical Specifications
Input
Input voltage range
Universal input (see Note 2)
NLP65-76xx version only
Input frequency range
Input current
(cold start)
120 Vac
230 Vac
Safety ground leakage current 120 Vac, 60 Hz
230 Vac, 50 Hz
Input current
120 Vac, with PFC
230 Vac, with PFC
120 Vac, without PFC
230 Vac, without PFC
Input fuse
UL/IEC127
Output
Total regulation
(line and load)
Main output
Auxiliary outputs
Rise time
At turn-on
Transient response
Temperature coefficient
Main output
25% step
at 0.1 A/µs
Overvoltage protection
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
Single and multiple
85 - 264 Vac
120 - 370 Vdc
47 - 63 Hz
17 A max.
32 A max
0.7 mA
1.4 mA
1.4 A
0.51 A rms
1.40 A rms
0.80 A rms
5 A, 250 Vac In live and neutral
±2.0%
±5.0%
1.0 s, max
5.0% or 250 mV
max. dev., 1ms max.
recovery to 1%
±0.02%/°C
125%, ±10%
Continuous
(See Note 6)