English
Language : 

NLP65-3322 Datasheet, PDF (1/3 Pages) Artesyn Technologies – 60W AC/DC Universal Input Switch Mode Power Supplies
NLP65-3322
Triple output
LOW POWER AC/DC POWER SUPPLIES 60W AC/DC Universal Input Switch Mode Power Supplies
1
• 5.0 x 3.0 inch card and 1.26 inch package (1U applications)
• Smallest industry standard package
• EN61000-3-2 compliance option (HCC)
• Overvoltage and short circuit protection
• 60W with free air convection cooling
• EN55022, EN55011 conducted emissions level B
• EN61000-4-2,-3,-4, -5, -6 immunity compliant
The NLP65-3322 is a 60W universal input AC/DC power supply on a 5 x 3 inch card
with a maximum component height of 1.26 inches for use in 1U applications. This
model has the option of input harmonic current correction in the same package size
making the series ideal for product designs that will need to comply with EN61000-3-
2 legislation. The NLP65-3322 provides 60W of output power with free air convection
cooling which can be boosted to 70W with 20CFM of air. The NLP65, with full
international safety approval, meets conducted emissions EN55022 level B and has
immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP65 series is designed for
use in low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, internet servers, cable modems and PABX’s. This list is not
exclusive as the generic feature set of the NLP65 series with industry standard output
configurations provides a solution for most low power applications including many
industrial applications.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Rise time
At turn-on
1.0s, max.
Transient response
Main output
25% step
at 0.1A/µs
5.0% or 250mV
max. dev., 1ms max.
recovery to 1%
Temperature coefficient
±0.02%/°C
Overvoltage protection Main outputs
125%, ±10%
Short circuit protection Cyclic operation
Yes, indefinite
Minimum output current Single and multiple
(See Note 6)
INPUT SPECIFICATIONS
Input voltage range
(See Note 1)
Universal input
85 to 264VAC
120 to 370VDC
Input frequency range
47Hz to 63Hz
Input surge current
(cold start)
120VAC
230VAC
17A max.
32A max.
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
0.7mA
1.4mA
Inrush current
230VAC
32A max.
Input current
120VAC, with PFC
230VAC, with PFC
120VAC, without PFC
230VAC, without PFC
1.05A rms
0.51A rms
1.40A rms
0.80A rms
Input fuse
UL/IEC127
250VAC S 3.15A
EMC CHARACTERISTICS (11,12)
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
EN55022, FCC part 15 (Note 11) Level B
EN55022, FCC part 15 (Note 11) Level A
EN61000-4-2, level 3 Perf. criteria 1
EN61000-4-2, level 4 Perf. criteria 1
EN61000-4-5, level 3 Perf. criteria 3
EN61000-4-4, level 3 Perf. criteria 1
EMC CHARACTERISTICS (continued) (11,12)
Radiated immunity
Conducted immunity
Surge
Fast transients
Radiated immunity
Conducted immunity
EN61000-4-3, level 3
EN61000-4-6, level 3
EN61000-4-5, level 2
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf. criteria 2
Perf. criteria 2
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time
230VAC, 50Hz
78ms @ 60W
Efficiency
75% typical
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Fixed
100kHz, ±5kHz
Approvals and
standards
(See Notes 9 and 12)
EN60950, UL1950,
cUL equivalent of
CSA C22.2 No. 950
Weight
283g (10 oz)
MTBF
MIL-HDBK-217F 150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 1, 4 and 10)
Operating temperature 0°C to +50°C
Non-operating
-40°C to +85°C
50°C to 70°C ambient,
convection cooled
1.65W/°C
Peak (0°C to +50°C, 60s)
See table
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000m max.
30,000m max.
Vibration (See Note 5) 5Hz to 500Hz
2.4G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
File Name: NLP65-3322.PDF Rev: 24 Feb 2000