English
Language : 

NLP250N-99S12J Datasheet, PDF (1/4 Pages) Artesyn Technologies – Single Output 250 W
POWER
Data Sheet
Total Power: 250 W
Input Voltage: 85 - 264 Vac
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Medical safeties
ƒƒ Active PFC and EN61000-3-2
compliant
ƒƒ 250 W on main channel with
forced air
ƒƒ Low profile fits 1U applications
ƒƒ U-Channel for maximum
thermal performance
ƒƒ Optional cover (CJ suffix)
ƒƒ 5 V standby output
ƒƒ 12 V fan output
ƒƒ Integrated control and
monitoring features
ƒƒ Overcurrent, overvoltage and
overtemperature protection
ƒƒ Compliance to EN55022-B
conducted noise standard
ƒƒ Dual AC fuses
ƒƒ RoHS compliant
ƒƒ Two year warranty
SAFETY
ƒƒ VDE0750/EN60950
IEC950/IEC60601-1
File No. 1177400-3336-0759
ƒƒ UL60601-1
File No. E186249
ƒƒ Certificate No. 40014041
ƒƒ CB Ref DE1-36628
NLP250 Medical Series
Single Output
Electrical Specifications
Input
Input voltage range
Universal input
Input frequency range
Input surge current
264 Vac (cold start)
Safety ground leakage 264 Vac, 50 Hz
current
Input current
120 Vac @ 250 W
230 Vac @ 250 W
Input fuse
UL/IEC127
Output
Maximum power
200 LFM forced air
250 LFM with cover
Adjustment range
Main output
Total regulation
(line and load)
Main output
Auxiliary outputs
Turn-on delay
@ 120 Vac Input
Transient response
Main output
50 - 100%
Step at 0.5 A/µs
Temperature coefficient
Overvoltage protection Main output
Short circuit protection Cyclic operation
Minimum output current
Auxiliary outputs
(See Note 8, page 3)
Singles
5 Vsb
12 V (fan)
85 - 264 Vac
47 - 63 Hz
40 A max.
150 µA
2.78 A rms
1.36 A rms
T6.4 AH, 250 Vac In live and neutral
250 watts
± 5%
± 2.0%
± 5.0%
2.0 s max.
5.0% or 250 mV
max. dev., 1 ms max
recovery to 1%
±0.02%/°C
115%, ± 5%
Continuous
0A
5 V @ 1.0 A
12 V @ 0.3A
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated