English
Language : 

NLP150L Datasheet, PDF (1/3 Pages) Artesyn Technologies – LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
NLP150L Series
Single and triple outputs
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150W AC/DC Universal Input Switch Mode Power Supplies 1
• 90VAC to 264VAC universal input range
• Provides low voltage outputs of 3.3V
• EN61000-3-2 compliant
• Overvoltage and short circuit protection
• Power fail detection
• Current sharing (on VA and VB)
• 3.8 x 6.8 x 1.26 inches
• UL, CSA and VDE safety approvals and CE-marked to LVD
• Compliance to EN55022-B conducted noise standard
• Compliance to EN55022-A radiated noise standard
• Meets all applicable and relevant immunity standards
EN61000-4-2, -3, -4, -5 and -6
The NLP150L series of 150 Watt AC/DC open frame power supplies are available with
single, triple or quad outputs. The single and triple output versions described in this
datasheet are housed in a 3.8 x 6.8 x 1.26 inch package. All NLP150L series power
supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support
current sharing. The power supplies are designed for use in 1U shelves or boxes, and are
primarily intended for networking applications that have a heavy logic content, such as
access concentrators, midrange routers, LAN switches and shared media hubs.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Patent No. 5600546 and 5652700
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Turn-on delay
@ 120VAC Input
2.0s, max.
Transient response
Main output
75% to 100%
step at 0.1A/µs
5.0% or 250mV
max. dev., 1ms max.
recovery to 1%
Temperature coefficient
±0.02%/°C
Overvoltage protection Main outputs
125%, ±10%
Short circuit protection Cyclic operation
Continuous
Minimum output current Singles and multiple
See table
INPUT SPECIFICATIONS
Input voltage range
(See Note 12)
Universal input
90 to 264VAC
Input frequency range
47Hz to 63Hz
Input surge current
264VAC (cold start)
40A max.
Safety ground
leakage current
264VAC, 60Hz
0.99mA
Input current
120VAC @ 150W
230VAC @ 150W
1.95A rms
1.10A rms
Input fuse
UL/IEC127
F3.15A H, 250VAC
EMC CHARACTERISTICS (11)
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
Level B
Level A
Compliant
Level 3
Level 3
EMC CHARACTERISTICS (continued) (11)
Surge
Fast transients
Radiated immunity
Conducted immunity
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level 3
Level 3
Level 3
Level 3
GENERAL SPECIFICATIONS
Hold-up time
120VAC @ 60Hz
20ms @ 150W
Efficiency (See Note 13) 120VAC @ 150W
73% typical
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Approvals and
standards pending
EN60950, VDE0805, IEC950
UL1950, CSA C22.2 No. 950
Weight
540g (19oz)
MTBF (@ 25°C)
MIL-HDBK-217F 350,000 hours min.
Bellcore
800,000 hours min.
ENVIRONMENTAL SPECIFICATIONS (8)
Thermal performance
Operating ambient,
(See derating curve)
Non-operating
50°C to 70°C ambient,
convection cooled
0°C to 50°C ambient,
convection cooled
0°C to 50°C ambient,
300LFM forced air
Peak (0°C to +50°C)
0°C to +50°C
-40°C to +85°C
Derate to
50% load
110W
150W
(See Note 3)
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Vibration (See Note 6) 5Hz to 500Hz
2.4G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
File Name: NLP150LST.PDF Rev: 24 June 2002