NFS40-7608J Datasheet, PDF (1/4 Pages) Artesyn Technologies – SIngle and triple output 40 - 50W | |||
|
Embedded Power for
Business-Critical Continuity
NFS40 Series
SIngle and
triple output
Rev.02.01.10_65
NFS40 Series
1 of 4
Total Power: 40 - 50W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs: Single, triple
Special Features
⢠5.0 x 3.0 x 1.2 inch package
(1U applications)
⢠Industry standard package
⢠Overvoltage and
short circuit protection
⢠40 W with free air convection
⢠50 W with 20 CFM forced air
⢠EN55022, EN55011
conducted noise level B
⢠UL, VDE and CSA
safety approvals
⢠Available RoHS compliant
⢠2 year warranty
Safety
⢠VDE0805/EN60950/
⢠IEC950/IEC1010
⢠File No. 10401-3336-0044
⢠License No. 2559
⢠UL1950 File No. E136005
⢠CSA C22.2 No. 950
⢠File No. LR41062C
Electrical Specifications
Input
Voltage adjustability:
Line regulation:
LL to HL, FL
Load regulation:
FL to NL
Transient response:
+5 V output on triples
Vout on singles
Main output
Auxiliary outputs
Main output
Auxiliary outputs
+5 V (1.5 - 3 A)
Temperature coefficient:
Overvoltage protection:
Output power limit:
Short circuit protection:
Output
Input voltage range:
All outputs
+5 V output
Primary power limited
Single outputs
Multiple outputs
Universal input
Input frequency range:
Max. input surge current:
Safety ground leakage current:
132 Vac, cold start
264 Vac, cold star
110 Vac, 60 Hz
230 Vac, 50 Hz
± 5.0%
± 5.0%
± 0.2%
± 1.0%
± 2.0%
± 5.0%
± 120 mV max. dev.
500 µs recovery
± 0.02%/°C
S3.15 A, 250 Vac In live and neutral
90 W input power limit
Continuous
Short term
85 - 264 Vac
120 - 370 Vdc
47-440 Hz
12 A max.
24 A max.
0.13 mA, max.
0.32 mA, max.
|
▷ |