English
Language : 

NFS350 Datasheet, PDF (1/4 Pages) Artesyn Technologies – Triple and quad output 350 Watt AC/DC universal input switch mode power supplies
[ 2 YEAR WARRANTY ]
NFS350 SERIES
Triple and quad output
• Autoranging input
• Overvoltage protection on main output
• Short circuit protection with auto restart
• Power fail detect
• VDE, UL, CSA and BABT approved
• Floating, fully adjustable fourth output
• 12VDC fan connection
• Conducted noise to EN55022-A, FCC level B
The NFS350 Series of triple and quad output 350 Watt open frame switchers is
designed for use with larger digital systems. High power density allows a very
compact system design. The advanced topology yields very well regulated outputs
that eliminate the need for inefficient dissipative regulators. The unique floating fourth
output allows a user configurable output voltage, adjustable from 4.5V to 30V, either
positive or negative, at up to 4A. These supplies are approved to UL, CSA, VDE and
BABT and their built-in line filter reduces conducted noise below FCC level B and VDE
0871 level A. NFS350 Series power supplies are suitable for a wide range of general
industrial applications, including process automation, robotics, networking, lighting
systems and telecoms. They are particularly suited for shelf power in miniature rack
systems or subracks.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage adjustability
+5V output
Auxiliaries
±5.0%
±3.0%
Line regulation
LL to HL, FL
Main output
±0.1% max.
Total regulation
See Note 4
±1.0%
Overshoot/undershoot At turn-on
0%
Transient response
+5.1V
150mV max. dev.
(35A to 50A step)
500µs recovery
Temperature coefficient All outputs
±0.02%/°C
Overvoltage protection +5V output, note 7
6.25V ±0.5V
Output power limit
550W, min.
Short circuit protection Foldback
See Note 7
Continuous
automatic recovery
Remote sense
Main output
Compensate
up to 200mV
Fan output current
Note C
12V/0.75A
INPUT SPECIFICATIONS
Input voltage range
Autoranging
90 to 132VAC
180 to 264VAC
Input frequency range
47Hz to 63Hz
Input surge current
110/230VAC
40A
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
0.6mA, max.
1.6mA, max.
PAGE 1
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, level A
EN55022
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
GENERAL SPECIFICATIONS
Hold-up time
230VAC, after power failure
230VAC, after PFD flag
20ms
5ms
Efficiency
230VAC, FL
70% typical
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Variable
Approvals and
standards
Safety
VDE0805, EN60950, IEC950
IEC1010, UL1950, BABT
CSA C22.2 No. 950
Weight
1.9kg (67.07oz)
MTBF
MIL-HDBK-217E
66,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating, see curve 0°C to +70°C
Non-operating
–40°C to +85°C
0°C to 50°C,
30CFM forced air
350W
50°C to 70°C,
30CFM forced air
Derate 8.75W/°C
Thermal switch
+85°C typical
trip temperature, Note 7
Peak power (60s)
450W
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max.
40,000 feet max.
Vibration, 5Hz to 500Hz Three orthogonal axes
random vibration,
10 min. test for each axis
2.4G rms