English
Language : 

NFS200 Datasheet, PDF (1/4 Pages) Artesyn Technologies – Triple and quad output 200 Watt AC/DC universal input switch mode power supplies
Patent No. 4912620
[ 2 YEAR WARRANTY ]
NFS200 SERIES
Triple and quad output
• 5.0 x 9.0 x 2.5 inch package
• Overvoltage and short circuit protection
• 200W with 30CFM
• Adjustable outputs
• Isolated outputs
• Power fail detect signals
• EN55022, EN55011 conducted emissions level A
• UL, VDE, CSA and BABT safety approvals
The NFS200 series is a 200W universal input AC/DC power supply in a 5 x 9 x
2.5 inch package. The NFS200 series has four multiple output models and has
proven itself to be highly reliable and versatile product for a wide range of
communication and industrial applications, with a very high peak capability on
the auxiliary outputs for drive and motor applications. The NFS200 provides
200W of output power with 30CFM of air. Standard features include overvoltage
and short circuit protection, adjustable outputs, isolated outputs and power fail
detect. The series, with full international safety approval and the CE mark,
meets conducted emissions EN55022 level A. The NFS200 series is designed
for use in medium power data networking, computer, telecom and industrial
applications such as servers, PABX's, printers and process automation.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage adjustability +5V output
±5.0%
Line regulation
LL to HL, FL
Main output
±0.1% max.
Load regulation
Main output
Auxiliary outputs
±2.0% max.
±2.5% max.
Overshoot/undershoot At turn-on
0%
Transient response
+5V
±200mV max. dev.
(20A to 30A step)
500µs recovery
to 1.0%
Temperature coefficient All outputs
±0.02%/°C
Overvoltage protection +5V output
6.25V±0.5V
Short circuit protection
Yes, with auto-recovery
Fan output current
(See Note 8)
J1: pins 3 and 4 12.1V @ 0.75A max.
INPUT SPECIFICATIONS
Input voltage range
Universal input
90VAC to 264VAC
130VDC to 370VDC
Input frequency range
47Hz to 63Hz
Input surge current
110VAC, 60Hz
230VAC, 50Hz
40A max.
80A max.
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
0.9mA max.
1.6mA max.
PAGE 1
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Level A
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
GENERAL SPECIFICATIONS
Hold-up time
110VAC
After PFD flag @ 200W
15ms
5ms
Efficiency
110/230VAC @ 200W
70% typ.
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency Variable
80 to 100kHz
Standards and
approvals
(See Note 9)
VDE0805, EN60950, IEC950
IEC1010, UL1950, BABT
CSA C22.2 No. 950
Weight
1.34kg (47.30oz)
MTBF (See Note 1)
MIL-HDBK-217E
84,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 3, 10)
Operating
Non-operating
0°C to +70°C
-40°C to +85°C
0°C to 50°C ambient,
30CFM forced air
200W
50°C to 70°C ambient, Derate linearly
30CFM forced air to 100W at 70°C
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max.
40,000 feet max.
Vibration
Three orthogonal
axes, random vibration,
10 minute test for
each axis
2.4G rms
5 to 500Hz