English
Language : 

NAN40 Datasheet, PDF (1/2 Pages) Artesyn Technologies – Dual and triple output 40 Watt AC/DC universal input switch mode power supplies
[ 2 YEAR WARRANTY ]
NAN40 SERIES
Dual and triple output
• 5.0 x 3.0 x 1.2 inch package (1U applications)
• Ideal for high volume designs
• Industry standard package
• Overvoltage and short circuit protection
• 40W with free air convection
• EN55022, EN55011 conducted emissions level B
The NAN40 series are 40W universal input AC/DC power supplies on a 5 x 3
inch card with a maximum component height of 1.2 inch for use in 1U
applications. These series are available with a wide range of models in the
industry standard 5 x 3 inch footprint at low cost making the series ideal for new
and existing high volume communication and industrial applications. The
NAN40 series provide 40W of output power with free air convection cooling with
a peak output of 50W for a maximum duration of 60 seconds. The NAN40
series are designed for use in high volume low power data networking,
computer and telecom applications such as hubs, routers, POS terminals, cable
modems and PABX's. This list is not exclusive as the generic feature set of both
series with industry standard output configurations provide a solution for most
high volume applications including many industrial applications.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Line regulation
Main output
Auxiliary outputs
±0.5%
±1.0%
Total regulation
Main output
Auxiliary outputs
±3.0%
±5.0%
Overshoot/undershoot At turn-on
<10%
Transient response
+5.1V
±150mV max. dev.,
(1.5A to 3A step)
500µs recovery
Temperature coefficient
±0.02%/°C
Overvoltage protection +5.1V output
6.25V ±0.75Vout
Output power limit
Primary power
limited
50W Pout, min.
110W Pin, max.
Short circuit protection Multiple output
30 seconds
INPUT SPECIFICATIONS
Input voltage range
Universal input
90 to 264VAC
120 to 370VDC
Input frequency range
47Hz to 440Hz
Input surge current
110VAC, cold start
15A
230VAC, cold start
32A
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
0.2mA
0.4mA
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076
Licence No. 70567, 1076 and 90354
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Certificate No. PS/605108
PAGE 1
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
level B
level A
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time
110VAC
230VAC
10ms @ 40W
60ms @ 40W
Efficiency
68% min. @ 40W
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Variable
Approvals and
standards
(See Note 8)
VDE0805, EN60950, IEC950
BABT, IEC1010, UL1950
CSA C22.2 No. 950
Weight
200g (7.06oz)
MTBF
MIL-HDBK-217F
150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
Non-operating
0°C to +70°C
-40°C to +85°C
0°C to 50°C ambient,
convection cooled
40W
50°C to 70°C,
Derate linearly
ambient conv. cooled
to half load
Peak (0°C to 50°C) max. 60s
50W
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non operating
10,000 feet max.
30,000 feet max.
Vibration
Three orthogonal axes,
2.4G rms
random vibration, 10 5Hz to 500Hz
minute test for each axis