English
Language : 

NAL40 Datasheet, PDF (1/3 Pages) Artesyn Technologies – 40W AC/DC Universal Input Switch Mode Power Supplies
NAL40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40W AC/DC Universal Input Switch Mode Power Supplies
1
• 5.0 x 3.0 x 1.2 inch package (1U applications)
• Ideal for high volume designs
• Industry standard package
• Overvoltage and short circuit protection
• 40W with free air convection
• EN55022, EN55011 conducted emissions level A
The NAL40 series are 40W universal input AC/DC power supplies on a 5 x 3 inch card
with a maximum component height of 1.2 inch for use in 1U applications. These series
are available with a wide range of models in the industry standard 5 x 3 inch footprint
at low cost making the series ideal for new and existing high volume communication
and industrial applications. The NAL40 meets level A conducted emissions. The NAL40
series provide 40W of output power with free air convection cooling with a peak output
of 50W for a maximum duration of 60 seconds. The NAL40 series are designed for use
in high volume low power data networking, computer and telecom applications such as
hubs, routers, POS terminals, cable modems and PABX’s. This list is not exclusive as
the generic feature set of both series with industry standard output configurations
provide a solution for most high volume applications including many industrial
applications.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Line regulation
Main output
Auxiliary outputs
Total regulation
Main output
Auxiliary outputs
Overshoot/undershoot At turn-on
Transient response
+5.1V
(1.5A to 3A step)
Temperature coefficient
Overvoltage protection +5.1V output
Output power limit
Primary power
limited
Short circuit protection
Multiple output
Single 12V, 15V,
24V and 48V
±0.5%
±1.0%
±3.0%
±5.0%
<10%
±150mV max. dev.,
500µs recovery
±0.02%/°C
6.25V ±0.75Vout
50W Pout, min.
110W Pin, max.
30 seconds
Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
Universal input
Input frequency range
Input surge current
Safety ground
leakage current
110VAC, cold start
230VAC, cold start
110VAC, 60Hz
230VAC, 50Hz
90 to 264VAC
120 to 370VDC
47Hz to 440Hz
15A
32A
0.2mA
0.4mA
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
level A
level A
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time
110VAC
230VAC
10ms @ 40W
60ms @ 40W
Efficiency
68% min. @ 40W
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Variable
Approvals and
standards
(See Note 9)
VDE0805, EN60950, IEC950
BABT, IEC1010, UL1950
CSA C22.2 No. 950
Weight
200g (7.06oz)
MTBF
MIL-HDBK-217F
150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
Non-operating
0°C to +70°C
-40°C to +85°C
0°C to 50°C ambient,
convection cooled
40W
50°C to 70°C,
Derate linearly
ambient conv. cooled
to half load
Peak (0°C to 50°C) max. 60s
50W
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non operating
10,000 feet max.
30,000 feet max.
Vibration
Three orthogonal axes,
2.4G rms
random vibration, 10
5Hz to 500Hz
minute test for each axis
File Name: NAL40.PDF Rev: 19 Nov 2001