English
Language : 

LPX100 Datasheet, PDF (1/2 Pages) Artesyn Technologies – Installation Notes LPX100 • Cover Enclosure Kit
POWER
Materials
ƒƒ 1 Base
ƒƒ 1 Cover
ƒƒ 4 M3x6mm Pan head screws with
spring washer
ƒƒ 4 M3x6mm countersunk screws
ƒƒ 1 M4 nut
ƒƒ 1 M4 star washer
ƒƒ 1 M4 spring washer
ƒƒ 1 Plastic insulator sheet
LPX100 Enclosure
Installation Notes LPX100 • Cover Enclosure Kit
LPX100 will fit the LPX5X, LPX10X-M, NPX4X-M, NPX2X-M
and NPX6X-M power supplies.
OUTPUT CONNECTOR
INPUT CONNECTOR
INSULATOR
GROUND STUD
(4X)STANDOFF
Installation Instructions and Notes
1
Place the insulator over the chassis as shown.
2
Place the power supply over the insulator as shown.
3
Align the 4x power supply to the chassis standoff.
4
Secure 4 pan head screws with washer provided with in kit as shown.
5
Place the cover over the power supply as shown.
6
Align the 4x cover to the U-bracket countersink holes.
7
Secure 4 countersink screws provided with in kit as shown.
8
Overall dimensions: 4.685 (119.0) x 2.945 (74.8) x 1.693 (43.0).
9
Base plate has three sets of customer mountings:
a. Bottom mounting (4X) M3 inserts. Max. screw penetration 0.0787 (2mm)
b. Side mounting (2X) 4mm clear holes plus 2 keyways. (See keyway detail)
c. Side mounting (4X) M3 inserts. Max. screw penetration 0.236 (6mm)
10
Ensure insulator is correctly fitted in base under PCB to maintain safety creepage and
clearances.
11
Ensure base is firmly connected to supply earth via the earth stud marked.
12
When using this enclosure, ensure that relevant safety standards (e.g. EN60950) are
complied with, in respect to creepage and clearance distances, and distances through
insulation.
13