LPT101-M Datasheet, PDF (1/4 Pages) Artesyn Technologies – Total Power: 80 - 130 Watts | |||
|
POWER
Data Sheet
Total Power: 80 - 130 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Triple
SPECIAL FEATURES
ÂÂ Medical and ITE safeties
ÂÂ Active power factor correction
ÂÂ 2â x 4â footprint
ÂÂ Less than 1U high
ÂÂ EN61000-3-2 compliant
ÂÂ Remote sense
ÂÂ Power fail
ÂÂ Adjustable main output
ÂÂ Built-in Class B EMI filter
ÂÂ Overvoltage protection
ÂÂ Overload protection
ÂÂ Thermal overload protection
ÂÂ LPX100 enclosure kit available
ÂÂ RoHS compliant
SAFETY
ÂÂ TUV
ÂÂ UL
ÂÂ CSA
ÂÂ NEMKO
ÂÂ AUSTEL
ÂÂ CB
ÂÂ CE
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
LPT100-M Series
130 Watts
Electrical Specifications
Input
Input raÂnge
90 - 264 Vac; 127 - 300 Vdc
Frequency
47 - 63 Hz
Inrush current
50 A max., cold start @ 25 °C
Efficiency
82% typical at full load
EMI/RFI
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz, 264 Vac input
Output
Maximum power
80 W for convection;
130 W with 200 LFM forced air
Adjustment range
All outputs adjustable: -20%, +10%, except for +24V output on
LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101-
M +10%, -15%
Hold-up time
10 ms @ 130 W load, 120 Vac input
Overload protection
Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3
Overvoltage protection 15 - 35% above nominal output
Logical Control
Power failure
Active LowTTL logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
|
▷ |