English
Language : 

LPT101-M Datasheet, PDF (1/4 Pages) Artesyn Technologies – Total Power: 80 - 130 Watts
POWER
Data Sheet
Total Power: 80 - 130 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Triple
SPECIAL FEATURES
ƒƒ Medical and ITE safeties
ƒƒ Active power factor correction
ƒƒ 2” x 4” footprint
ƒƒ Less than 1U high
ƒƒ EN61000-3-2 compliant
ƒƒ Remote sense
ƒƒ Power fail
ƒƒ Adjustable main output
ƒƒ Built-in Class B EMI filter
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ LPX100 enclosure kit available
ƒƒ RoHS compliant
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ CSA
ƒƒ NEMKO
ƒƒ AUSTEL
ƒƒ CB
ƒƒ CE
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
LPT100-M Series
130 Watts
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac; 127 - 300 Vdc
Frequency
47 - 63 Hz
Inrush current
50 A max., cold start @ 25 °C
Efficiency
82% typical at full load
EMI/RFI
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz, 264 Vac input
Output
Maximum power
80 W for convection;
130 W with 200 LFM forced air
Adjustment range
All outputs adjustable: -20%, +10%, except for +24V output on
LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101-
M +10%, -15%
Hold-up time
10 ms @ 130 W load, 120 Vac input
Overload protection
Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3
Overvoltage protection 15 - 35% above nominal output
Logical Control
Power failure
Active LowTTL logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.