LPS61 Datasheet, PDF (1/3 Pages) Artesyn Technologies – Total Power: 60 - 80 Watts | |||
|
POWER
Data Sheet
Total Power: 60 - 80 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
ÂÂ Universal input
ÂÂ 3â x 5â footprint
ÂÂ Remote sense
ÂÂ Built in EMI filter
ÂÂ Low output ripple
ÂÂ Adjustable output voltage
ÂÂ Overload protection
ÂÂ 110 KHz switching frequency
ÂÂ RoHS compliant
ÂÂ LPX60 enclosure kit available
SAFETY
ÂÂ UL
UL 60950-1
CAN/CSA-C22.2 60950-1
E132002
ÂÂ NEMKO
ÂÂ CB
ÂÂ CE
EN 60950-1
IEC 60950-1
Mark (LVD)
LPS60 Series
60 Watts
Electrical Specifications
Input
Input range
85 - 264 Vac (wide range)
120 - 300 Vdc
Frequency
47-440 Hz
Inrush current
<18 A peak @ 115 Vac, <36 A peak @230 Vac, cold start @ 25 °C
Input current
1.5 A max. (RMS) @ 115 Vac
Efficiency
70% typical at full load
EMI filter
FCC Class B conducted; CISPR 22 Class B conducted; EN55022
Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
<0.5 mA @ 50/60 Hz; 264 Vac input
Output
Maximum power
60 W for convection; 80 W with 30 CFM forced air
Adjustment range
-5, +10% minimum
Hold-up time
20 ms @ 60 W load, 115 Vac nominal line
Overload protection
Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5 V output; 5.7 - 6.7 Vdc.
Other outputs 10% to 25% above nominal output
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
|
▷ |