English
Language : 

LPS360-M Datasheet, PDF (1/3 Pages) Artesyn Technologies – Adjustable main output
POWER
Low Power Data Sheet
LPS360-M Series
360 Watt AC-DC Power Supply
Total Power: 200 - 360 W
Input Voltage: 90 - 264 Vac
120 - 300 Vdc
Outputs: Single
SPECIAL FEATURES
ƒƒ Medical and ITE safeties
ƒƒ Active power factor correction
ƒƒ 3” x 5” footprint
ƒƒ Less than 1U high
ƒƒ EN61000-3-2 compliant
ƒƒ Remote sense
ƒƒ Power fail
ƒƒ Adjustable main output
ƒƒ Level B Conducted EMI - Class I
or Class II inputs
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ 12 V fan output
ƒƒ LPX200 enclosure kit available
ƒƒ 5 V Standby output
ƒƒ Remote Inhibit
ƒƒ PMBus commands
ƒƒ RoHS compliant
ƒƒ Digital I2C interface
ƒƒ Designed to meet Class I and
Class II
ƒƒ Dual AC fuses
ƒƒ Suitable for BF Type applications
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ cULus
ƒƒ CB
ƒƒ CE
ƒƒ CCC
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD & EMC)
Approval
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac; 120 - 300 Vdc
Frequency
47 - 63 Hz
Inrush current
50 A max., cold start @ 25 °C
Efficiency
Up to 93% at full load
EMI/RFI
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Power factor
0.99 typical
Safety ground leakage
current
150 µA @ 132 Vac, 60 Hz for class I, 300 µA @ 264 Vac, 60 Hz for class II
Output
Maximum power
200 - 240 W (see de-rating) for convection, 360 W with 400 LFM of forced air
Adjustment range
12 V and 24 V models, -0%, +15%; 15 V and 48 V models, -5%, +10%;
36 V model, -15%, +0%
Standby output
5 V @ 1A convection, 2 A with forced air
Fan output
12 V @ 0.5 A convection, 1 A forced air
Hold-up time
20 ms @240 W, 220 Vac input; 12 ms @ 360 W
Overload protection
Short circuit protection on all outputs. Case overload protected @ 110 - 160%
above rating
Overvoltage protection
15 - 50% above nominal output
Logical Control
Power failure
Open collector logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.