English
Language : 

LPS172 Datasheet, PDF (1/4 Pages) Emerson Network Power – Active power factor correction
POWER
Data Sheet
Total Power: 100 - 175 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Active power factor correction
ƒƒ IEC EN61000-3-2 compliance
ƒƒ Wide range adjustable output:
Remote sense on main output
ƒƒ Single wire current sharing
ƒƒ Power fail and remote inhibit
ƒƒ Built-in EMI filter
ƒƒ Low output ripple
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ DC power good
ƒƒ 5 V standby output
ƒƒ 12 V Aux output
ƒƒ Optional cover (-C suffix)
ƒƒ RoHS compliant
SAFETY
ƒƒ VDE 0805/EN60950 (IEC950)
ƒƒ UL
UL1950
ƒƒ CB
Certificate and report
ƒƒ CSA
CSA 22.2-234 Level 3
ƒƒ CE
Mark (LVD)
ƒƒ NEMKO EN 60950/EMKO-TUE
LPS170 Series
175 Watts
Electrical Specifications
Input
Input range
85 - 264 Vac; 120-300 Vdc
Frequency
47 - 63 Hz
Inrush current
38 A max, cold start @ 25°C
Efficiency
75% typical at full load
EMI filter
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power Factor
0.99 typical
Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power
110 W convection (75 W with cover)
175 W with 30 CFM forced air (130 W with cover)
Adjustment range
2:1 wide ratio minimum
Standby outputs
5 V @ 2 A regulated ±5%
Hold-up time
20 ms @175 W load at nominal line
Overload protection
Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection
10% to 40% above nominal output
Aux output
12 V @ 1 A -5 %, +10%