LCM600Q-A Datasheet, PDF (1/7 Pages) Artesyn Technologies – 600 Watt Bulk Front End | |||
|
POWER
Data Sheet
Total Power: 600 W
# of Outputs: Single
Outputs: 12 to 60 V
Optional 5.0 V standby
SPECIAL FEATURES
ÂÂ 600 W output power
ÂÂ Low cost
ÂÂ 2.4â x 4.5â x 7.5â
ÂÂ 7.41 W/cu-in
ÂÂ Industrial/Medical safety
 -40 °C to 70 °C with derating
ÂÂ Optional 5 V @ 2 A housekeeping
ÂÂ High efficiency: 89% typical
ÂÂ Variable speed âSmart Fansâ
ÂÂ DSP controlled front end
ÂÂ Conformal coat option
 ± 20% adjustment range
ÂÂ Margin programming
ÂÂ OR-ing FET
ÂÂ Terminal block input option
COMPLIANCE
ÂÂ EMI Class B
ÂÂ EN61000 Immunity
SAFETY
ÂÂ UL/CSA
ÂÂ TUV
ÂÂ CB Report
ÂÂ CCC
ÂÂ UL/CSA
ÂÂ TUV
ÂÂ CB Report
UL60950-1/CSA
C22.2 No. 60950-1
EN60950-1
IEC60950-1
GB4943, GB9254
and GB17625
ES60601-1/CSA
C22.2 No. 60601-1
EN60601-1
IEC60601-1
LCM600
600 Watt Bulk Front End
Electrical Specifications
Input
Input raÂnge
85 - 264 Vac (Operating)
115/230 Vac (Nominal) Input through standard IEC connector/
TERMINAL BLOCK
Frequency
47 - 440 Hz, Nominal 50/60
Input fusing
Internal 10 A fuses, both lines fused
Inrush current
⤠25 A peak, either hot or cold start
Power factor
0.99 typical, meets EN61000-3-2
Harmonics
Meets IEC 1000-3-2 requirements
Input current
8 A RMS max input current, at 100 Vac
Hold up time
20 ms minimum for main O/P, at full rated load
Efficiency
> 89% at full load
Leakage current
< 0.3 mA at 264 Vac
ON/OFF power switch
N/A
Power line transient
MOV directly after the fuse
Isolation
Isolation: PRI-Chassis 2500 Vdc Basic
PRI-SEC 4000 Vac Reinforced 2xMOPP
SEC-Chassis 500 Vdc
92.00
90.00
88.00
86.00
84.00
82.00
80.00
78.00
76.00
LCM600Q Ef ciency Without the 5 Vsb
25
50
75
100
Loading %
100 Vac
230 Vac
|
▷ |