English
Language : 

LCM1000L Datasheet, PDF (1/6 Pages) Artesyn Technologies – 1000 Watt Bulk Front End
POWER
Data Sheet
LCM1000
1000 Watt Bulk Front End
Total Power: 1000 W
# of Outputs: Single
Outputs: 12 to 48 V
Optional 5.0 V standby
SPECIAL FEATURES
ƒƒ 1000 W output power
ƒƒ Low cost
ƒƒ 2.5” x 5.2” x 10.0”
ƒƒ 7.7 Watts per cubic inch
ƒƒ Industrial/Medical safety
ƒƒ -40 °C to 70 °C with derating
ƒƒ Optional 5 V @ 2 A
housekeeping
ƒƒ High efficiency: 90% typical
ƒƒ Variable speed “Smart Fans”
ƒƒ DSP controlled
ƒƒ Full rating with reverse airflow
ƒƒ Conformal coat option
ƒƒ ± 10% adjustment range
ƒƒ Margin programming
ƒƒ OR-ing FET
ƒƒ Low acoustic noise
COMPLIANCE
ƒƒ EMI Class A; Class B with internal
modification option
ƒƒ EN61000 Immunity
ƒƒ RoHS 2
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac (Operating)
115/230 Vac (Nominal)
TERMINAL BLOCK
Frequency
47 - 440 Hz, Nominal 50/60
Input fusing
Internal 30 A fuses, both lines fused
Inrush current
≤ 25 A peak, either hot or cold start
Power factor
0.99 typical, meets EN61000-3-2
Harmonics
Meets IEC 1000-3-2 requirements
Input current
Hold up time
12 A RMS max input current, at 100 Vac
20 ms minimum for Main O/P, at full rated load
Efficiency
> 90% typical at full load / 230 Vac nominal
Leakage current
< 0.4 mA at 264 Vac
ON/OFF power switch
N/A
Power line transient
Isolation
MOV directly after the fuse
PRI-Chassis 2500 Vdc Basic
PRI-SEC 4000 VAC Reinforced 2xMOPP
SEC-Chassis 500 Vdc
SAFETY
ƒƒ ULcUL Recognized ITE (UL60950-1)
ƒƒ ULcUL Recognized Medical
(ANSI/AAMI ES60601-1)
ƒƒ TUV-SuD ITE + Medical
(EN60950-1 and EN60601-1)
ƒƒ CE LVD (EN60950-1 + ROHS)
ƒƒ BSMI
ƒƒ CB Report
- through Demko for IEC60950-1
- through TUV-SuD for IEC60601-1
ƒƒ CCC Approval
92.00
90.00
88.00
86.00
84.00
82.00
80.00
78.00
76.00
LCM1000L-T Ef ciency Without the 5 Vsb
25
50
75
100
Loading %
100 Vac
230 Vac