EXQ60D Series
Dual positive output
DC/DC CONVERTERS 60W High Efficiency DC/DC Converters
• Two positive outputs
• Output voltage tracking
• High efficiency
• Approved to EN60950 (TÜV Rheinland), UL/cUL1950
• Operating baseplate temperature of -40°C to +100°C
• Up to 100% load imbalance
• Trim function
• No minimum load
• Complies with ETS 300 019-1-3/2-3
• Fully compliant with ETS 300 386-1
The EXQ60 is a new high efficiency, open frame, isolated 60 Watt converter series in an
industry standard quarter-brick footprint. The EXQ60 delivers very high output current at
low voltages, and excellent useable power density for today's high end applications.
The first two models in the series feature an input voltage range of 33 to 75VDC and are
available in output voltages of 5V/3.3V and 3.3V/2.5V. The output voltage on each
model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the
models are 91% for the 5V/3.3V and 90% for the 3.3V/2.5V version. The EXQ60 series
also has a remote on/off capability. Overcurrent and overvoltage protection features are
included as standard. With full international safety approval including EN60950, (TÜV
Rheinland) and UL/cUL1950, the EXQ60 reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
1
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Both outputs
±10%
Setpoint accuracy
Both outputs (See Note 1) ±1% max.
Output voltage
(over all line and
load conditions)
5V/3.3V
3.3V/2.5V
4.75V < Vo1 < 5.23V
3.20V < Vo2 < 3.43V
3.18V < Vo1 < 3.48V
2.39V < Vo2 < 2.60V
Minimum load
Both outputs
0%
Ripple and noise
20MHz bandwidth 60mV pk-pk max.,
20mV rms max.
Transient response
50% to 75% and back 120mV/80mV
peak dev. settling time to 1.0%, no external cap.
100µs
Short circuit protection
Both outputs
Tracking
Outputs track
start-up and shutdown
INPUT SPECIFICATIONS
Input voltage range
48Vin nominal
33 to 75VDC
Input current
No load
Remote OFF
60mA max.
20mA max.
UVLO turn ON voltage
UVLO turn OFF voltage
33V (typ)
30V (typ)
Start-up time
Nominal line
8ms (typ)
Active high remote ON/OFF
Logic compatibility
ON
OFF
(See Note 4)
Open Collector ref. to -input
Open circuit or >4VDC
<1.2VDC
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
EN55022 with external filter
EN55022 with external filter
EN55022
Level A
Level B
Level B
EN61000-4-2
8kV (NP), 15kV (RP)
EN61000-4-2
6kV (NP), 8kV (RP)
EN61000-4-3
10V/m (NP)
EN61000-4-6
10V (NP)
EN61000-4-6
10V (NP)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation
Input/output
Input/baseplate
1500VDC
1500VDC
Input fuse
5.0A slow blow
Switching frequency
Fixed
400kHz (5V/3V3)
325kHz (3V3/2V5)
Approvals and standards
(See Notes 2 and 3)
UL/cUL1950, EN60950
TÜV Rheinland
Weight
45g (1.6 oz)
MTBF
MIL-HDBK-217F
@ 25°C, 100% load
ground benign
>270,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating baseplate
temperature
Non-operating
-40°C to +100°C
-40°C to +125°C
File Name: EXQ60D.PDF Rev: 24 July 2002