English
Language : 

EXB30-24D05-3V3 Datasheet, PDF (1/2 Pages) Artesyn Technologies – 30W High Efficiency DC/DC Converters
EXB30 Series
Dual positive output
DC/DC CONVERTERS 30W High Efficiency DC/DC Converters
• Two independent positive outputs
• Output voltage tracking
• High efficiency
• Approved to EN60950, UL1950, CSA C22.2 No. 950
• Operating ambient temperature of -40°C to +70°C
(natural convection)
• Up to 100% load imbalance
• Separate trim on each output
• No minimum load
• Complies with ETS 300 019-1-3/2-3
• Fully compliant with ETS 300 386-1
The EXB30 Dual series are isolated dual positive-output DC/DC converters. The products
are designed using a high-efficiency synchronous rectification topology. They feature two
independent fully regulated outputs, which are individually trimmable. The EXB30 Dual
employs Dynamic Current Allocation such that maximum current can be drawn from either
output with a total output current capability of 6A. No minimum load is required for either
output. In addition, these products incorporate a tracking feature such that both outputs rise
together with their output differential never exceeding 0.7 Volts during start-up. A remote
on/off and latching overvoltage protection for both outputs are included as standard. These
latches are enabled by default, but can be disabled by the user.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
1
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Both outputs
±11% min.
Voltage accuracy
Both outputs
±1.5% max.
Line regulation
Low line to high line
Low line to high line
Vout1 ±0.4%
Vout2 ±0.4%
Load regulation
Full load to no load
±0.4%
Minimum load
Both outputs
0%
Ripple and noise
20MHz bandwidth
150mV pk-pk max.
30mV rms max.
Temperature coefficient
±0.02%/°C
Transient response
50% to 75% and back
peak dev. settling time to 1.0%, no external cap.
150mV
400µs
Short circuit protection Both outputs
Isc 8A rms (See Note 3)
Continuous
automatic recovery
Tracking
Max. differential 0.7V during
start-up and in operation
INPUT SPECIFICATIONS
Input voltage range
24Vin nominal
48Vin nominal
18 to 36VDC
36 to 75VDC
Input current
No load
Remote OFF
150mA max.
4mA max.
UVLO turn ON voltage All inputs (See Note 2)
UVLO turn OFF voltage All inputs (See Note 2)
94% typ.
86% typ.
Start-up time
Nominal line
20ms max.
Active high remote ON/OFF
Logic compatibility
Open Collector ref. to -input
ON
Open circuit voltage
4.5VDC
OFF
0.6VDC
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
EFT DC power
EFT signal
Radiated field enclosure
Surges indoor signal
Conducted (DC power)
Conducted (signal)
Input transients
EN55022 with external filter Level A
EN55022 with external filter Level B
EN55022 (See App. Note 109) Level B
EN61000-4-2
8kV (NP), 15kV (RP)
EN61000-4-2
6kV (NP), 8kV (RP)
EN61000-4-4
2kV (NP), 4kV (LFS)
EN61000-4-4
1kV (NP), 2kV (LFS)
EN61000-4-3
10V/m (NP)
EN61000-4-5
500V (RP)
EN61000-4-6
10V (NP)
EN61000-4-6
10V (NP)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
Basic insulation
Input/output
Input fuse 24V
Input fuse 48V
(See Note 4)
Switching frequency
Fixed
Approvals and
standards
(See Notes 4, 6)
Weight
MTBF (See Application MIL-HDBK-217
Note 109)
See table
1500VDC
3.5A slow blow
2.0A slow blow
280kHz
EN60950
Bi-national UL1950
CSA C22.2 No. 950
52g (1.84 oz)
250,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
temperature
Non-operating
-40°C to +70°C,
See curves
-55°C to +105°C
ETS 300 019-2-3
Classes T3.1 to T3.5
Air temperature
Low: IEC 68-2-1
High: IEC 68-2-2
Change: IEC 68-2-14
-40°C
+70°C
-40°C to +70°C
Relative humidity
IEC 68-2-56
IEC 68-2-30
10% to 100% RH
Condensation
File Name: EXB30D.PDF Rev: 28 Jan 2002