English
Language : 

ERM Datasheet, PDF (1/4 Pages) Artesyn Technologies – Fire potection meets EN45545-2
POWER
Data Sheet
Total Power: 10 Watts
Input Voltage: 12 V, 24 V, 48 V,
72 V or 110 V
# of Outputs: Single, Dual
SPECIAL FEATURES
ƒƒ Encapsulated
ƒƒ Wide 4:1 input range
ƒƒ 1” x 2” DIP package
ƒƒ 3000 Vac rms I/O isolation
ƒƒ Single and dual output
ƒƒ OCP, OVP, OTP protection
ƒƒ Remote On/Off
ƒƒ High efficiency: 88%
ƒƒ Fire potection meets EN45545-2
ƒƒ Railway EMC standard
EN50121-3-2
SAFETY
ƒƒ UL/cUL 62368-1 (60950-1)
ƒƒ IEC/EN 62368-1 (60950-1)
ƒƒ IEC/EN 50155 (IEC60571)
ERM Series
10 Watts
Electrical Specifications
Input
Input ra­nge
Efficiency2
Output
Voltage tolerance
Line regulation
Load regulation
Noise/ripple
OCP and S/C protection
Overvoltage protection
Switching frequency
Temperature co-efficient
Isolation
I/O isolation
Insulation resistance
Insulation capacitance
9 to 36 Vdc; 18 to 75 Vdc; 40 to 160 Vdc
88% @ 24 Vo
±1.0%
±0.2%
Single output: ±0.5%; Dual output ±1.0%
150 mV
Hiccup
Latched
320 KHz
±0.02 /°C
3000 Vac rms min.
1000 Mohm
1500 pF
Environmental Specifications
Operating ambient temperature range -40 °C to +85 °C (with derating)
Storage temperature
-50 °C to +125 °C
Humidity
5% to 95% (non-condensing)