DSR850-2 Datasheet, PDF (1/5 Pages) Artesyn Technologies – 850 Watts Multi-Output | |||
|
Embedded Power for
Business-Critical Continuity
DSR850-2
Preliminary
PDU
850 Watts Multi-Output
RoHS
Rev. 04.20.07
DSR850-2
1 of 5
This is a 2U Power Supply
Assembly (PSA) primarily for an
ATX type product, comprising of
one or two AC to 12V Power
Supplies (PSU), and a Power
Distribution Unit (PDU), mechani-
cal housing and output wiring
harness with connectors. Where
only one PSU is required, a blank
module will be installed in the
remaining slot.
Special Features
PSU = 12vdc/70A 5vsb/2.5A
⢠Wide Range AC Input; 90-264vac
⢠Active Power Factor Correction
⢠Active AC Inrush Current Control
⢠Active Current Share +12v main
⢠Droop Current Share 5v Stand-By
⢠Hot Plug Operation
⢠N+1 Redundant (w/two PSUâs)
⢠Internal ORâing main 12v and stand-by
⢠Internal Cooling fans 40mm
⢠Red/Green Bi-Color LED Status
⢠I2C Communication Interface Bus
⢠INTEL, SSI Std. Logic Timing
⢠INTEL, SSI Std. FRU Data Format
⢠Intel PSMI Protocol
⢠Internal Fan Speed Control
⢠EN61000-3-2 Harmonic Compliance
⢠EMI Level âBâ Conducted & Radiated
PDU
⢠Six +12v/16A Rails with
240VA protection
⢠+5V 44A
⢠+3V3 24A
⢠-12V 0.5A
⢠+5VSB 2.5A
⢠Output Harness and Connectors
⢠One Year Warranty
PSU 1
PSU 2
PSA
TM
Electrical Specifications
Available upon request
Input
Input range
90-264 Vac (wide range)
Frequency
AC Inrush current
Efficiency
Power factor
AC input leakage current
Hold up time
47-63 Hz, single phase ac
55 A AC maximum inrush current (any condition)
>82% AC to +12 V > 70% all outputs at full load
0.99 typical
1.50 mA @ 240 Vac
20 mS minimum
Conducted EMI
EN55022 Class B, CFR47 FCC Pt15B, Class B
ETS300-132-1, EN61000-3-2, EN61000-3-3, GR-1089
Radiated EMI
AC input connector
Output PSU
EN55022 Class B, CFR47 FCC Pt15A, Class B limit
IEC320-C14 with all safety approvals
Main DC voltage
+12v @ 70 A
Stand-By Voltage
Minimum Load
Regulation
Overcurrent
Overvoltage
5.0v @ 2.5A
No Minimum load required
+12 Vdc; +/-5%
5.0 Vsb +/-5%
77-105A latches off if Overcurrent state exceeds 1 second
+12 V; 13.2 â 14.4 V, 5.0vsb; 5.7 â 6.5 V
Undervoltage
See table page 2
Safety
UL/cUL 60950 (UL Recognized)
IEC60950-1/EN60950-1
Compliance
CB test report and CB Certificate to
IEC60950-1
CE Mark
China CCC
|
▷ |