English
Language : 

DSR850-2 Datasheet, PDF (1/5 Pages) Artesyn Technologies – 850 Watts Multi-Output
Embedded Power for
Business-Critical Continuity
DSR850-2
Preliminary
PDU
850 Watts Multi-Output
RoHS
Rev. 04.20.07
DSR850-2
1 of 5
This is a 2U Power Supply
Assembly (PSA) primarily for an
ATX type product, comprising of
one or two AC to 12V Power
Supplies (PSU), and a Power
Distribution Unit (PDU), mechani-
cal housing and output wiring
harness with connectors. Where
only one PSU is required, a blank
module will be installed in the
remaining slot.
Special Features
PSU = 12vdc/70A 5vsb/2.5A
• Wide Range AC Input; 90-264vac
• Active Power Factor Correction
• Active AC Inrush Current Control
• Active Current Share +12v main
• Droop Current Share 5v Stand-By
• Hot Plug Operation
• N+1 Redundant (w/two PSU’s)
• Internal OR’ing main 12v and stand-by
• Internal Cooling fans 40mm
• Red/Green Bi-Color LED Status
• I2C Communication Interface Bus
• INTEL, SSI Std. Logic Timing
• INTEL, SSI Std. FRU Data Format
• Intel PSMI Protocol
• Internal Fan Speed Control
• EN61000-3-2 Harmonic Compliance
• EMI Level “B” Conducted & Radiated
PDU
• Six +12v/16A Rails with
240VA protection
• +5V 44A
• +3V3 24A
• -12V 0.5A
• +5VSB 2.5A
• Output Harness and Connectors
• One Year Warranty
PSU 1
PSU 2
PSA
TM
Electrical Specifications
Available upon request
Input
Input range
90-264 Vac (wide range)
Frequency
AC Inrush current
Efficiency
Power factor
AC input leakage current
Hold up time
47-63 Hz, single phase ac
55 A AC maximum inrush current (any condition)
>82% AC to +12 V > 70% all outputs at full load
0.99 typical
1.50 mA @ 240 Vac
20 mS minimum
Conducted EMI
EN55022 Class B, CFR47 FCC Pt15B, Class B
ETS300-132-1, EN61000-3-2, EN61000-3-3, GR-1089
Radiated EMI
AC input connector
Output PSU
EN55022 Class B, CFR47 FCC Pt15A, Class B limit
IEC320-C14 with all safety approvals
Main DC voltage
+12v @ 70 A
Stand-By Voltage
Minimum Load
Regulation
Overcurrent
Overvoltage
5.0v @ 2.5A
No Minimum load required
+12 Vdc; +/-5%
5.0 Vsb +/-5%
77-105A latches off if Overcurrent state exceeds 1 second
+12 V; 13.2 – 14.4 V, 5.0vsb; 5.7 – 6.5 V
Undervoltage
See table page 2
Safety
UL/cUL 60950 (UL Recognized)
IEC60950-1/EN60950-1
Compliance
CB test report and CB Certificate to
IEC60950-1
CE Mark
China CCC