English
Language : 

DS750PED Datasheet, PDF (1/7 Pages) Artesyn Technologies – 750 Watts Distributed Power System
POWER
Data Sheet
DS750PED
750 Watts Distributed Power System
Front-end Bulk Power
Total Output Power:
750 W continuous
Wide Input Voltage:
90 to 264 Vac
SPECIAL FEATURES
ƒƒ 750 W output power
ƒƒ High-power and short form factor
ƒƒ 1U power supply
ƒƒ High-density design: 16.4 W/in3
ƒƒ Active Power Factor Correction
ƒƒ EN61000-3-2 Harmonic compliance
ƒƒ Inrush current control
ƒƒ 80plus Platinum efficiency
ƒƒ N+1 or N+N redundant
ƒƒ Hot-pluggable
ƒƒ Active current sharing
ƒƒ Full digital control
ƒƒ PMBus compliant
ƒƒ Accurate input power reporting
ƒƒ Compatible with Artesyn’s Universal
PMBus GUI
ƒƒ Reverse airflow option
ƒƒ Two-year warranty
COMPLIANCE
ƒƒ Conducted/Radiated EMI Class A
Limits + 6 dB margin
ƒƒ EN61000-4-11
SAFETY
ƒƒ UL/cUL
ƒƒ Demko +CB Report
ƒƒ CE Mark
ƒƒ CCC
ƒƒ BSMI
Electrical Specifications
Input
Input range
Frequency
Efficiency
Max Input current
Inrush current
Conducted EMI
Radiated EMI
Power factor
ITHD
Leakage current
Hold-up time
90 - 264 Vac
47 Hz to 63 Hz
94.0% peak
10.0 Arms @ 90 Vac
55 Apk
Class A with 6 dB margin
Class A with 6 dB margin
>0.9 beginning at 20% load
10%
1.75 mA
10 ms at full load
Output
Nominal setting
Total output regulation range
Dynamic load regulation range
Output ripple
Output current
Current sharing
Capacitive loading
Start-up from AC to output
Output rise time
Main DC Output
MIN
NOM MAX
-0.20%
12
0.20%
11.4 V
12.6 V
11.4 V
12.6 V
120 mVp-p
0.5 A1
62.5 A
Within ±5% of full load rating
2000 uF
40,000 uF
2200 ms
5 ms
50 ms
Standby DC Output
MIN
NOM
-1%
12
11.4 V
11.4 V
0.1 A
N/A
47 uF
2 ms
MAX
1%
12.6 V
12.6 V
120 mVp-p
3.0 A
680 uF
1700 ms
60 ms
1 Minimum current for transient load response testing only. Unit is designed to operate and be within output regulation range at zero load.