DS2900 Datasheet, PDF (1/7 Pages) Emerson Network Power – 2900 Watts Distributed Power System | |||
|
POWER
Data Sheet
Distributed Power Bulk Front-End
Total Output Power: 2900 Watts
+3.3 Vdc Stand-by Output
Wide Range Input Voltage:
180 - 264 Vac
DS2900
2900 Watts
Distributed Power System
Special features
ÂÂ Active power factor correction
ÂÂ EN61000-3-2 harmonic compliance
ÂÂ Active AC inrush control
ÂÂ 2U X 3U form factor
ÂÂ 24.8 W / in3
ÂÂ +12 Vdc Output
ÂÂ +3.3 Vdc stand-by
(5 V standby - consult factory)
ÂÂ No minimum load required
ÂÂ Hot plug operation
ÂÂ N + 1 redundant
ÂÂ Internal ORâing fets
ÂÂ Active current sharing (10 - 100% load)
ÂÂ Built-in cooling fan (40 mm x 40 mm)
ÂÂ I2C communication interface bus
ÂÂ PMBus compliant
ÂÂ EEPROM for FRU data
ÂÂ 2 LED (Green and Amber)
ÂÂ Internal fan speed control
ÂÂ INTEL, SSI Std. logic timing
ÂÂ INTEL, SSI Std. FRU data format
PSMI V2.12
ÂÂ Full digital control
ÂÂ Two year warranty
ÂÂ Compatible with Universal PMBus GUI
Electrical Specifications
Input
Input range:
Frequency:
180 - 264 (2900 W)
47-63 Hz, single phase AC
Inrush current:
50 Apk maximum inrush current
Efficiency:
> 91% typical at nom line 50% load
Conducted EMI:
FCC Subpart J EN55022 Class A
Radiated EMI:
FCC Subpart J EN55022 Class A. Meets intent of NEBS, Bellcore
GR-1089
Power factor:
0.99 typical
Leakage current:
1.40 mA @ 240 VAC
Hold up time:
10 mS minimum
SAFETY
ÂÂ UL/cUL 60950 (UL Recognized)
ÂÂ NEMKO+ CB Report EN60950
ÂÂ EN60950
ÂÂ CE Mark
ÂÂ China CCC
|
▷ |