DS1200-3 Datasheet, PDF (1/5 Pages) Artesyn Technologies – Distributed Power System
POWER
Data Sheet
Distributed Power Bulk Front-End
Total Output Power: 1200 Watts
+3.3 Vdc Stand-by Output
Wide Range Input Voltage: 90 -
264 Vac
Special Features
ƒƒ Active power factor correction
ƒƒ EN61000-3-2 harmonic compliance
ƒƒ Active AC inrush control
ƒƒ 1U X 2U form factor
ƒƒ 21.71 W/in3
ƒƒ +12 Vdc Output
ƒƒ +3.3 Vdc or +5.0 Vdc stand-by
ƒƒ No minimum load required
ƒƒ Hot plug operation
ƒƒ N + 1 redundant
ƒƒ Internal OR’ing fets
ƒƒ Active current sharing
(10 - 100% load)
ƒƒ Built-in cooling fan
(40 mm x 28 mm)
ƒƒ I2C communication interface bus
ƒƒ PMBus compliant
ƒƒ EEPROM for FRU data
ƒƒ Red/green bi-color LED status
ƒƒ Internal fan speed control
ƒƒ Fan Fail Tach Output Signal
ƒƒ Full digital control
ƒƒ Two year warranty
Safety
ƒƒ UL/cUL 60950 (UL Recognized)
ƒƒ NEMKO+ CB Report EN60950
ƒƒ EN60950
ƒƒ CE Mark
ƒƒ China CCC
DS1200
1200 Watts
Distributed Power System
Electrical Specifications
Input
Input range:
180 - 264 (1200 W)
90 - 264 (1000 W)
Frequency:
Inrush current:
Efficiency:
Conducted EMI:
Radiated EMI:
Power factor:
Leakage current:
Hold up time:
Output
47-63 Hz, single phase AC
40 Apk maximum inrush current
> 91% typical at high line 50% load
FCC Subpart J EN55022 Class B
FCC Subpart J EN55022 Class B
0.99 typical
1.40 mA @ 240 VAC
12 ms minimum
Main DC voltage:
+12 V @ 100 A (high line)
+12 V @ 81.6 A (low line)
Stand-By:
Adjustment range:
+3.3 Vsb @ 6 A (5 V @ 4 A available)
±5% on +12V only using I2C
Regulation:
+12 Vdc; +5%/-5%
+3.3 Vsb; +5%/-5%
Over current:
+12 Vdc; latches off if overcurrent lasts over 1 second,
otherwise it is auto recovery (See Table 1 next page) +3.3 Vsb, 9 A
max (hiccup mode)
Over voltage:
+12 Vdc; 13.2 - 14.4 Vdc
+3.3 Vsb; 3.76 - 4.30 Vdc
Under voltage:
Turn-on delay:
Main output rise time:
+12 Vdc; 9 - 10.8 V (latch off)
2 second max, 5 - 50 mS, monotonic rise
5 - 50 mS, monotonic rise