English
Language : 

DS1100SLPE-3-001 Datasheet, PDF (1/7 Pages) Artesyn Technologies – 1100 Watts Distributed Power System
POWER
Data Sheet
DS1100SLPE
1100 Watts Distributed Power System
Front-end Bulk Power
Total Output Power:
1100 W continuous
Wide Input Voltage:
90 to 264 Vac
SPECIAL FEATURES
ƒƒ 1100 W output power
ƒƒ High-power and short form factor
ƒƒ 1U power supply
ƒƒ High-density design: 26 W/in3
ƒƒ Active Power Factor Correction
ƒƒ EN61000-3-2 harmonic compliance
ƒƒ Inrush current control
ƒƒ 80plus Platinum Efficiency
ƒƒ N+1 or N+N Redundant
ƒƒ Hot-pluggable
ƒƒ Active current sharing
ƒƒ Full digital control
ƒƒ PMBus compliant
ƒƒ Accurate input power reporting
ƒƒ Compatible with Artesyn’s Universal
PMBus GUI
ƒƒ Reverse airflow option
ƒƒ Two-year warranty
COMPLIANCE
ƒƒ EMI Conducted/Radiated Class A
Limits + 6 dB margin
ƒƒ EN61000-4 Electromagnetic
compatibility
ƒƒ ROHS 6/6
SAFETY
ƒƒ UL/cUL 60950 (UL Recognized)
ƒƒ DEMKO+ CB Report EN60950
ƒƒ CE Mark
ƒƒ China CCC
ƒƒ BSMI
Electrical Specifications
Input
Input range
Frequency
Efficiency
Max input current
Inrush current
Conducted EMI
Radiated EMI
Power factor
ITHD
Leakage current
Hold-up time
90 - 264 Vac
47 Hz to 63 Hz
94.0% peak
14.5 Arms
55 Apk
Class A +6 dB margin
Class A +6 dB margin
> 0.9 beginning at 20% load
10%
1.75 mA
16 ms at full load
Output
Nominal setting
Total output regulation range
Dynamic load regulation range
Output ripple
Output current
Main DC Output
MIN
NOM
MAX
-1%
12
+1%
11.64 V
12
12.36 V
11.64 V
12.36 V
180 mVp-p
0.5 A1
90.0 A
Standby DC Output
MIN
NOM
MAX
-1%
3.3
1%
3.14 V
3.3
3.46 V
3.14 V
3.46 V
45 mVp-p
0.1 A
3.0 A
Current sharing
Capacitive loading
Start-up from AC to output
Output rise time
Within ±5.625A of each other from
25% to 100% load
500 uF
11,000 uF
2200 ms
5 ms
50 ms
100 uF
2 ms
N/A
680 uF
1700 ms
60 ms
Note: Outputs shall be isolated from the chassis ground by at least 50 V.