English
Language : 

DPF950 Datasheet, PDF (1/2 Pages) Artesyn Technologies – Dual output 950 Watt AC/DC PFC front-end for distributed power architectures
[ 2 YEAR WARRANTY ]
DPF950 SERIES
Dual output
• 950W front end
• EN61000-3-2 compliant
• 12.75 x 8.0 x 4.93 inch (including panel)
• Hot-pluggable, N+1 redundancy
• Full set of status signals
• EN55022, EN55011 conducted emissions level B
• UL, VDE, CSA and BABT safety approvals
The DPF950 is a 950W universal input AC/DC front end power supply in a fully
enclosed hot pluggable case with built-in fan, front panel with handle, IEC input
connector, on/off switch and DIN output signal connector. Providing dual 48V
and 5V outputs with a full set of status signals, the DPF950 is designed as a
slot-in front end for distributed power systems. The DPF950 provides 950W of
output power and is fully compliant with EN61000-3-2. Standard features
include current sharing and full protection against overvoltage, overload and
short circuit. Remote or local system monitoring is possible via a full set of
status signals that include fan fail, DC good, remote inhibit and current
monitoring. The DPF950, with full international safety approval and the CE mark,
meets conducted emissions EN55022 level B. The DPF950 is designed for use
as a front end in medium power communication applications adopting
distributed power architecture. The DPF950 can be used in conjunction with our
complete range of 3 to 200W DC/DC converters to fully configure a distributed
power system.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage set point
-46.5V ±0.50V
Total regulation
(Full load to no load)
Main output
Auxiliary output
±5.0%
±2.5%
Rise time
At turn-on
3.0s, max.
Transient response
Main output
50% to 100%
step at 1.0A/µs
3V max. dev.,
1ms recovery
to 1.0%
Ripple and noise
Main output
0Hz to 30MHz (Note 5) Auxiliary output
480mV pk-pk,
50mV pk-pk
Overvoltage protection latching
-55V to - 60V
Output power limit
950W
Short circuit protection Cyclic operation
Auto recovery
Current sharing
3V droop, 1/3 Load
to full load
±10% sharing
above 5A load
INPUT SPECIFICATIONS
Input voltage range
90 to 264VAC
Input frequency range
47Hz to 63Hz
Input surge current
220VAC, cold start @ 25°C 36A typ.
Input surge
300VAC
20ms
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
0.2mA
0.4mA
Input current
90VAC, 950W
14A rms max.
Input fuse
UL, IEC approved
250VAC, 20A
Power factor
110VAC
0.99
220VAC
0.98
EMC CHARACTERISTICS
Radiated noise
EN55022/11, FCC part 15
Conducted noise
EN55022/11
FCC part 15
Harmonic current emm. EN61000-3-2
Electrical fast
transients/bursts
EN61000-4-4
Surge susceptibility EN61000-4-5
Level A
Level B
Level A
Compliant
Level 3
Level 3
GENERAL SPECIFICATIONS
Hold-up time
120VAC, 60Hz FL
20ms @ 950W
Efficiency
90Vin, >66% rated load
78% min.
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
50kHz
Approvals and
standards
VDE0805, EN60950, IEC950
UL1950, BABT
CSA C22.2 No. 950
Weight
6.4kg (14Ibs)
MTBF
MIL-HDBK-217F
@ 25°C
100,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient, FL 0°C to +50°C
Non-operating
-40°C to +70°C
50°C to 70°C ambient,
convection cooled
Derate to
50% load
Cooling
Built-in fan
Relative humidity
Non-condensing
5% to 85% RH
Altitude
Operating
Non-operating
10,000 feet max.
40,000 feet max.
Vibration
5Hz to 500Hz
2.4G rms peak
Shock
MIL-STD-810E
516.4 Part IV
PAGE 1