English
Language : 

CXA20 Datasheet, PDF (1/3 Pages) Artesyn Technologies – 20W DC/DC Converters
CXA20 Series
Single and dual output
DC/DC CONVERTERS 20W DC/DC Converters
1
• 4:1 input voltage range
• No minimum load on singles
• 6A on 3.3V output (@ 48Vin) at 50˚C in still air
• Wide operating temperature with overtemperature
protection
• ±10% output voltage trim
• Remote On/Off control
• Overvoltage protection
The CXA20 is a new 20W addition to the CXA family of open-frame, isolated, DC/DC
converters. The five model series features a 4:1 input voltage range of 18 to 75VDC,
making it suitable for a wide variety of communications and distributed power
applications. With its 2.0 x 1.6 inch industry standard footprint, the CXA20 provides
an easy upgrade option for new and existing Artesyn customers seeking a high-
performance, cost-effective power supply. The CXA20 is available in output voltages
of 3.3V, 5V, 12V, ±5V and ±12V. The 3.3V version delivering up to 6A is fully rated to
20W. Typical efficiency for the CXA20 is 83 percent. The CXA20 offers remote on/off,
as well as overvoltage, overtemperature and short circuit protection features.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage accuracy
±1.0%
Line regulation
(LL to HL)
Singles/dual positives
Dual negatives
±0.1%
±0.1%
Load regulation
(not incl. cross reg.)
Full load to minimum load
S3V3
Singles/dual positives
Dual negatives
±0.2%
±0.1%
±0.1%
Minimum load
Singles
Duals (for imbalanced loads)
None
10%
Ripple and noise
20MHz bandwidth
S3V3, S05, D05
S12, D12
All models
75mV pk-pk max.
100mV pk-pk max.
20mV rms max.
Temperature coefficient
±0.02%/°C
Overvoltage protection
See Application Note 107
Short circuit protection Hiccup
Short <20mΩ
Continuous
automatic recovery
Transient response
25% load step
±2.0% max. dev.,
300µs recovery to
within total error band
Load cross regulation
(See Note 1)
10% load to full load,
either output
±7.0%
INPUT SPECIFICATIONS
Input voltage range
48Vin nominal
18 to 75VDC
Input fuse
HRC recommended
2.0A
Max. input rise
and fall time
48V ETS300-132
5V/ms
UVLO turn ON voltage (See Note 4)
UVLO turn OFF voltage (See Note 4)
92%
86%
Remote ON/OFF
Logic compatibility
ON
OFF
CMOS/TTL/Open Collector
Open circuit or >2VDC
<1.2VDC
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
EFT DC power
EFT signal
Radiated field enclosure
Surges indoor signal
Conducted (DC power)
Conducted (signal)
Input transients
EN55022, ext. cap. (Note 5) Level A
EN55022, external filter,
Level B
VDE0878, 48V models
EN55022-B
See App. Note 107
EN61000-4-2 8kV (NP), 15kV (RP)
EN61000-4-2 6kV (NP), 8kV (RP)
EN61000-4-4 2kV (NP), 4kV (LFS)
EN61000-4-4 1kV (NP), 2kV (LFS)
EN61000-4-3 10V/m (NP)
EN61000-4-5 500V (RP)
EN61000-4-6 10V (NP)
EN61000-4-6 10V (NP)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
Overtemp. shutdown
Isolation voltage
Switching frequency
Approvals and standards
(See Notes 6,7,8)
Material flammability
Weight
MTBF
(Representative model
48S05 @ 48Vin)
See table
120˚C
Input/output test voltage
1500VDC
Fixed
400kHz
EN60950
UL1950 File No. E136005
UL94V-0
26g (0.92 oz)
MIL-HDBK-217F
400,000 hours
Parts stress method
Ground Benign @ 25°C
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
ETS 300 019-2-3
Air temperature
Relative humidity
Operating ambient
temperature
Non-operating
-40°C to +60°C,
(See Note 9)
-55°C to +125°C
Classes T3.1, 3.2, 3.3, 3.5
Low: IEC 68-2-1
High: IEC 68-2-2
Change: IEC 68-2-14
-40°C
+60°C
-40°C to +60°C
IEC 68-2-56
IEC 68-2-30
10% to 100% RH
Condensation
File Name: CXA20.PDF Rev: 11 Jan 2002