CNS650-M Datasheet, PDF (1/8 Pages) Artesyn Technologies – Type BF ready | |||
|
POWER
Data Sheet
Total Power: 650 Watts
Input Voltage: 90 - 264 V
# of Outputs: Single
CNS650-M Series
650 Watt AC-DC Power Supplies
SPECIAL FEATURES
ÂÂ Designed for forced air and natural
convection cooling
ÂÂ Medical and ITE safety approvals,
2x MOPP
 PMBus® interface
ÂÂ Active current share with OR-ing
FET
ÂÂ Dual fused
ÂÂ Type BF ready
ÂÂ Active Power Factor Correction,
61000-3-2 compliant
ÂÂ Built-in Class B EMI filter
ÂÂ Less than 1U high
ÂÂ 4â x 6â U-channel construction
(open-frame or end-fan variants
available for 12 V)
ÂÂ <500 mW no-load power
consumption
 80 PLUS® certified (-ME model)
ÂÂ Three-year warranty (consult
factory for extended terms)
SAFETY
ÂÂ UL/CSA
ÂÂ TÃV
ÂÂ DEMKO
ÂÂ CB
ÂÂ CCC
ÂÂ CE
ES60601-1/C22.2
No. 60601-1
UL 60950-1/C22.2
No. 60950-1
EN 60601-1
EN 60950-1
IEC 60950-1
IEC 60601-1
IEC 62368-1
GB4943.1/GB9254;
GB17625.1
LVD, RoHS
Electrical Specifications
Input
Input voltage raÂnge
Frequency
Inrush current
Leakage current
No load power
Output
Maximum power
Adjustment range
Holdup time
Fan output
Standby output
INDUSTRIAL
90 - 264 Vrms
47 - 63 Hz (360 - 440 Hz with higher leakage)
50 Apk, cold start
<300 µA
< 500 mW
650 W, forced-air cooling (750 W peak)
400 W, free-air natural convection cooling (650 W peak)
-0% / +15%
20 ms @ 400 W
12 V @ 1.0 A (forced air)
12 V @ 0.5 A (natural convection)
5 V @ 2.0 A (forced air)
5 V @ 1.0 A (natural convection)
|
▷ |