English
Language : 

AXA04F18-L Datasheet, PDF (1/2 Pages) Artesyn Technologies – POWER 20 Watts
POWER
Data Sheet
AXA Series
20 Watts
Total Power: 20 W
Input Voltage: 24 or 48 V
# of Outputs: Single and Dual
SPECIAL FEATURES
ƒƒ Package size 1.0” x 1.0” x 0.4”
ƒƒ Ultra-wide 4:1 input range:
9 - 36 Vin, 18 - 75 Vin
ƒƒ Very high efficiency up to 90%
ƒƒ Operating temperature range:
-40 °C to +85 °C
ƒƒ Output voltage adjustable
ƒƒ I/O isolation voltage 1500 VDC
ƒƒ Remote ON/OFF control
ƒƒ Metal case with isolated baseplate
ƒƒ CSA/UL/IEC/EN 60950-1
Safety Approval
SAFETY
ƒƒ cUL/UL 60950-1
ƒƒ IEC/EN 60950-1
Electrical Specifications
Input
Input range
Efficiency
Output
Voltage tolerance
Line regulation
Load regulation
Noise/ripple
Overload protection
Short circuit protection
Switching frequency
Isolation
I/O isolation
Insulation resistance
Insulation capacitance
9 - 36 Vdc, 18 - 75 Vdc
89% @ 12 Vo
±1.0%
±0.2% for single output, ±0.5% for dual output
±0.2% for 12 V, 15 V and 24 V, ±0.5% for 3.3 V and 5 V.
±1.0% for dual output
3.3 V and 5 V Models: 75 mV; 12 V and 15 V Models: 100 mV;
24 V Models: 150 mV; Dual Output Models: 100 mV
150% typ of Io max, hiccup
Hiccup mode
330 KHz
I/O: 1500 Vdc
1000 Mohm
1500 pF
Environmental Specifications
Operating ambient temperature range -40 °C to +85 °C
Storage temperature
-50 °C to +125 °C
Humidity
5% to 95% non-condensing
MTBF
346 Khrs calculated