ANC A-DN SERIES
VER : A_2 update : 2010.07.09
AC-DC Switching Power Supply
15 Watts
ELECTRICAL SPECIFICATIONS
Model No. ( Dual、Triple Output )
Max Output Wattage (W)
Voltage
Frequency (Hz)
Input
Current (Full load)
Inrush Current (<2ms)
Leakage Current
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Load Regulation (5-100%) (typ.)
Output
Minimum Load
Maximum Capacitive Load
Ripple
Noise
Efficiency
Hold-up Time
Switching Frequency
Protection
Over Power Protection
Over Voltage Protection
Isolation
Short Circuit Protection
Input-Output (V.AC)
Input-FG (V.AC)
Output-FG (V.AC)
Operating Temperature
Environment
Storage Temperature
Temperature Coefficient
Humidity
MTBF
Physical
Dimension (L x W x H)
Case Material
Weight
Cooling Method
Safety
EMC
Agency Approvals
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
ANC-5D-DN
ANC-12D-DN ANC-15D-DN ANC-5S12D-DN ANC-5S15D-DN
15W
15.6W
15W
14.8W
14.5W
90-264 VAC or 120-370 VDC
47-440 Hz
280 mA max. (115 VAC) / 170 mA max. (230 VAC)
10 A max. (115 VAC) /20 A max. (230 VAC)
0.75 mA max.
±5V
±12V
±15V
5/±12
5/±15
±5%
±2%
±1500
±650
±500
2000/±200
2000/±150
±0.5%
±1% / ±5%
±3%
±2% / ±5%
0%
5V 10% (200 mA)
470-23,000µF depending on model
<0.2% Vout +40mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
71%
76%
65%
68%
68%
15 ms min.
100 kHz
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000V
1500V
500V
-25°C…+70°C (with derating)
-40°C…+85°C
±0.02%/°C
95% RH
>200,000 h @ 25°C (MIL-HDBK-217F)
3.58 x 3.39 x 1.85 Inches ( 91.0 x 86.0 x 47.0 mm ) Tolerance ±0.5 mm
Plastic resin with Fiberglass (flammability to UL 94V-2)
200 g
Free air convection
UL/cUL, CE, TUV
EN 55022 class B
EN 55024
1.All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor.