English
Language : 

AKC_16 Datasheet, PDF (2/4 Pages) Arch Electronics Corp. – AC-DC Power Module
AKC SERIES
VER : C_2 update : 2016.07.28
AC-DC Power Module
20 Watts
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Voltage
90-264 VAC or 100-375 VDC
Frequency (Hz)
47-440 Hz
Current (Full load)
400 mA max. (115 VAC) / 270 mA max. (230 VAC)
Input
Inrush current (<2ms)
30 A max. (115 VAC) / 50 A max. (230 VAC)
Leakage Current
0.25 mA
External Fuse (recommend) 2 A slow blow type
Power Saving
230V < 0.5W
Ripple
<0.2% Vout +40mV max (Vp-p)
Output
Noise
<0.5% Vout +50mV max (Vp-p)
Hold-up time (typ.)
13 ms min.
Over current protection
Above 105% rated output power
Protection
Over voltage protection
Zener diode clamp
Short circuit protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Isolation
Input-FG (V.AC)
3000V
Output-FG (V.AC)
500V
Operating temperature
-25°C…+70°C (with derating)
Storage temperature
-40°C…+85°C
Environment Temperature coefficient
0.02%/°C
Humidity
95% RH
MTBF
>400,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.73 x 1.87 x 0.85 Inches ( 69.5 x 47.5 x 21.7 mm ) Tolerance 0.5 mm
Physical
Case Material
Weight
Plastic resin (flammability to UL 94V-0)
110 g
Cooling method
Free air convection
Safety
Agency Approvals
CE, UL/cUL, CB
EMC
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 55022 class B
EN 55024
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. The triple output required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices; however they may not meet all listed specification.
3. Load regulation for triple output:
Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 20% to 100% balanced on all outputs.
4. Cross regulation for dual output: asymmetrical load 25% / 100% FL
Cross regulation for triple output:
Main output 100% load, auxiliary 100%,other auxiliary25% to 100%.
Auxiliary outputs(V2 and V3):main output 100% load, auxiliary 100%,
other auxiliary 25% to 100% or main output 25%,auxiliary 25%,other auxiliary 25% to 100%.
5. It's necessary Varistor 14S471K at L / N input side in parallel.
6. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-