English
Language : 

SZA100_16 Datasheet, PDF (1/5 Pages) Arch Electronics Corp. – Open Frame Switching Power Supply
SZA100 SERIES
KEY FEATURES
 Open Frame Switching Power Supply
 Universal Input: 85-265 VAC
 Single Output
 <0.3W No Load Input Power (48Vout <0.5W)
 5 VDC to 48 VDC Output
 Ultra Compact Size: 4.05 x 2.04 x 1.36 Inches
 3-Year Product Warranty
VER :A_2 update : 2016.09.01
AC-DC Switching Power Supply
100 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
SZA100-5S
SZA100-12S
SZA100-15S SZA100-24S SZA100-48S
Max Output Wattage (Free air Convection) (W)
Max Output Wattage (with 20CFM FAN) (W)
Voltage
80 W
100 W
85-265 VAC or 120-370 VDC
Frequency (Hz)
47-63 Hz
Input
Current (Full load)
3 A max. (115 VAC) / 2 A max. (230 VAC)
Inrush Current (<2ms)
40 A max. (115 VAC) / 80 A max. (230 VAC)
Leakage Current
0.75 mA max.
Voltage (V.DC.)
5V
12V
15V
24V
48V
Voltage Accuracy
±2%
Current (Free air Convection) (mA) max 12,000
6,665
5,336
3,336
1,667
Current (with 20CFM FAN) (mA) max
18,000
8,330
6,670
4,170
2,084
Line Regulation (LL-HL) (typ.)
±1%
Output
Load Regulation (5-100%) (typ.)
Maximum Capacitive Load (at 230VAC)
±1%
35,000µF
24,640µF
13,860µF
5,600µF
1,638µF
Ripple
150mV
100mV
100mV
110mV
150mV
Noise
150mV
150mV
150mV
200mV
280mV
Efficiency (at 230V)
80%
86%
86%
88%
88%
Trim
±10%
Hold-up Time
10 ms min.
Protection
Over Power Protection
Over Voltage Protection
Auto recovery
Zener diode clamp
Short Circuit Protection
Auto recovery
Input-Output (V.AC)
3000VAC or 4242VDC
Isolation
Input-FG (V.AC)
1500V
Output-FG .(V.AC)
500V
Operating Temperature
-25°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Temperature coefficient
Environment
Humidity
±0.02%/°C
95% RH
MTBF
>130,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
Physical
Dimension (L x W x H)
Weight
4.05 x 2.04 x 1.36 Inches ( 102.75 x 51.7 x 34.5 mm ) Tolerance 0.5 mm
220 g
EMC
Cooling Method
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
Free air convection
EN 55022 Class B (Pending)
EN 55024 (Pending)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-