English
Language : 

POL10.16 Datasheet, PDF (1/3 Pages) Arch Electronics Corp. – Input under Voltage Protection
POL10/16 SERIES
VER : A_0 update : 2014.04.25
DC-DC Brick
10/16 A
KEY FEATURES
 Input under Voltage Protection
 Over Current Protection (Hiccup Mode)
 Short Circuit Protection (Hiccup Mode)
 Over Voltage Protection (Self-recovery) * *
 Over Temperature Protection (Self-recovery)
 Remote ON/OFF Control
 Remote Sense
 Output Voltage Trim
 Monotonic Start-Up Into Pre-Biased Outputs *
 Meet UL94V-0 flammability requirements
 Size: 2.0 x 0.5 x 0.33 Inches (POL16-05)
2.0 x 0.55 x 0.47 Inches (others Model)
 3-Years Product Warranty
*POL10-05 and POL16-12 without this function
**POL16-05 without this function
DESCRIPTION
POL series are high performance SIP POL models, whose feature include wide
range of input voltage, high power density and perfect protection functions.
This series include BUCK and BOOST models, the output current covering 10A
and 16A two levels. The output voltage can be set arbitrarily in the rating range.
All models can be used in DPA or IBA. This series which conform to the RoHS6
requirement are suitable for telecom devices, server, network and industry
devices power supply
ELECTRICAL SPECIFICATIONS
Conditions: TA = -40 - 85°C, Vin = 4.5 - 5.5 / 3 - 5.5V / 10 - 14 VDC, Vout = 3.3 / 0.75 – 3.3 / 0.85 - 5 V DC, unless otherwise notes.
Model No.
Input
Output
Protection
Environment
Physical
Other
Voltage (V.DC.) (max.) (Continuous)
Operating Voltage (V.DC.)
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage Set Point (V.DC.) (typ.)
Voltage Trim Range (V.DC.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
Over Power Protection
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
(TA = -40°C to +85°C (-40°F to +185°F ))
Humidity
MTBF
Dimension (L x W x H)
Tolerance 0.5 mm
Weight
Remote
On/Off Voltage
Low level (V.DC.)
High level (V.DC.)
POL10-05
POL16-05
POL16-12
6V
5.8V
16V
5V (4.5~5.5V)
3.3V (3~5.5V)
12V (10~14V)
10A
23A
18A
0.3W
0.2W
0.7W
3.3V
3.3V
1.2V
3.2~3.4V
0.75~3.3V
0.85~5V
10A
16A
16A
1%
1%
1.5%
2%
70 mV
50 mV
<3.3V:50 mV
≧3.3V: 75 mV
95%
0.9Vout: 85%
0.85Vout: 80%
1.0Vout: 86%
1.0Vout: 83%
1.2Vout: 87.5%
1.2Vout: 84%
1.5Vout: 89.5%
1.5Vout: 86%
1.8Vout: 91%
1.8Vout: 87.5%
2.5Vout: 93%
2.5Vout: 88%
3.3Vout: 94.5%
3.3Vout: 90.5%
5.0Vout: 92%
Hiccup mode
Hiccup mode
105~130%
(Self-recovery)
─
105~130%
(Self-recovery)
Hiccup mode
Threshold:125°C / Hysteresis:5°C (typ.)
Self-recovery (The values are obtained by measuring the temperature of the PCB bottom near
the thermal resistor.)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C
0.5 % Vout / °C
0.02 % Vout / °C
95% RH
1.5 Million Hours
(Telcordia SR332; Vin = 5 / 3.3 / 12 V; 80% load; Airflow = 1.5 m/s (300
FLM); TA = 40°C (104°F)
POL16-05: 2.0 x 0.5 x 0.33 Inches ( 50.8 x 12.7 x 8.4 mm )
others: 2.0 x 0.55 x 0.47 Inches ( 50.8 x 14.0 x 12.0 mm )
6g
-0.2~0.5V
0.4V (max.)
-0.2~0.5V
2.0~5.0V
1.5~5.8V
2.0~5.0V
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-