English
Language : 

PLF16_16 Datasheet, PDF (1/2 Pages) Arch Electronics Corp. – Fully Isolated Plastic Case with IP65 Level
PLF16 SERIES
KEY FEATURES
 Fully Isolated Plastic Case with IP65 Level
 Constant Current
 Universal Input: 90-264 VAC
 With P.F.C. Function, PF>0.93
 High Efficiency up to 86%
 Turn-on Delay < 250ms
 Protections: Over Load / Over Voltage / Short Circuit
.Over Temperature(optional)
 High Reliability & Double Layered PCB
 3-Years Product Warranty
VER : A_4 update : 2015.05.15
LED Power
16 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max output wattage ( W )
Voltage (Note1)
Frequency (Hz)
Input
Power factor
Current (full load)
Inrush current
Leakage current
Voltage (V.DC.) (max)
Operation Voltage (Note2)
Current (mA)
Output
Load Regulation (Min-Max) (typ.)
Ripple & Noise (max) (Note3)
Current Regulation (at 230VAC) (Note4)
Efficiency (typ) (at 230VAC)
Over Temperature protection(optional)
Protection
Over voltage protection
Short circuit protection
Isolation
Input-Output (V.AC)
Operating temperature
Storage temperature
Environment Temperature coefficient
Humidity
MTBF
Dimension (L x W x H)
Physical
Weight
Cooling method
Safety Standards
Safety & EMC EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
PLF16-1050
PLF16-700
PLF16-350
16.38W
16.8W
16.8W
90-264 VAC
47~63 Hz
PF>0.93 at full load (115/230 VAC)
0.6A max. (115 VAC) / 0.3A max. (230 VAC)
40 A max. (Cold Start at 230 VAC)
<0.25mA
15.6V
24V
48V
11~15.6VDC
16.8~24VDC
33.6~48 VDC
1050
700
350
±4%
3Vp-p
±5%
84%
86%
86%
Auto recovery
Auto recovery
Auto recovery
4000V
-30°C…+70°C (with derating)
-40°C…+85°C
0.1%/°C
95% RH
>906,500 h @ 25°C (MIL-HDBK-217F)
3.47 x 1.69 x 1.1 Inches ( 88.0 x 43.0 x 28.0 mm ) Tolerance 0.5 mm
150 g
Free air convection
EN61347-1、EN61347-2-13
EN 55015
EN 61547
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319