English
Language : 

MSC Datasheet, PDF (1/6 Pages) Arch Electronics Corp. – AC-DC Medical
MSC SERIES
KEY FEATURES
„ Switching Power Modules for PCB Mounting
„ Fully Encapsulated Plastic Case
„ Universal Input Range 90-264VAC, 47-440 Hz
„ Regulated Output
„ Low Ripple and Noise
„ Isolation Class II
„ CE, CB, UL, cUL, TUV Approvals
„ 3-Years Product Warranty
VER : B_6 update : 98.04.09
AC-DC Medical
40 Watts
ELECTRICAL SPECIFICATIONS
Model No. ( Single Output )
Max output wattage ( W )
Voltage (V.DC.)
Current (mA) max
Voltage set accuracy
Output
Line regulation (Typ.)
Load regulation (1-100%) (Typ.)
Minimum load
Efficiency (Typ)
MSC-3.3S
26.4W
3.3V
8000
±2%
0.5%
1%
1%
75%
MSC-5S
40W
5V
8000
±2%
0.5%
1%
1%
79%
MSC-9S
40W
9V
4444
±2%
0.5%
1%
1%
82%
MSC-12S
40W
12V
3333
±2%
0.5%
1%
1%
83%
MSC-15S
40W
15V
2666
±2%
0.5%
1%
1%
83%
MSC-24S
40W
24V
1667
±2%
0.5%
1%
1%
83%
Model No. ( Dual Output )
Max output wattage ( W )
Output
Voltage (V.DC.)
Current (mA) max
Voltage set accuracy
Line regulation (Typ.)
Load regulation (10-100%) (Typ.)
Cross regulation (Typ.)
Minimum load
Efficiency (Typ)
MSC-5D
40W
Output 1
Output 2
+5V
-5V
4000
4000
±2%
0.5%
1% (symmetric load)
5%
10%
79%
MSC-12D
40W
Output 1
Output 2
+12V
-12V
1666
1666
±2%
0.5%
1% (symmetric load)
5%
10%
83%
MSC-15D
40W
Output 1
Output 2
+15V
-15V
1333
1333
±2%
0.5%
1% (symmetric load)
5%
10%
83%
Model No. ( Dual Output )
Max output wattage ( W )
Output
Voltage (V.DC.)
Current (mA) max
Voltage set accuracy
Line regulation (Typ.)
Load regulation (10-100%) (Typ.)
Cross regulation (Typ.)
Minimum load
Efficiency (Typ)
MSC-5S12S
40W
Output 1
Output 2
5V
12V
5000
±3%
1250
±5%
0.5%
5%
2% (symmetric load) 6% (symmetric load)
1%
7%
25%
80%
MSC-5S24S
40W
Output 1
Output 2
5V
24V
5000
±3%
625
±5%
0.5%
5%
2% (symmetric load) 6% (symmetric load)
1%
7%
25%
80%
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-