English
Language : 

BRH100_16 Datasheet, PDF (1/4 Pages) Arch Electronics Corp. – Input under Voltage Protection
BRH100 SERIES
VER : A_1 update : 2015.03.16
DC-DC Brick
72/80/96 Watts
KEY FEATURES
 Input under Voltage Protection
 Over Current Protection (Hiccup Mode)
 Short Circuit Protection (Hiccup Mode)
 Over Voltage Protection (Hiccup Mode)
 Over Temperature Protection (Self-recovery)
 Remote ON/OFF Control
 Remote Sense *
 Output Voltage Trim
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 2.28 x 1.45 x 0.38 Inches (BRH100-24S)
 Size: 2.28 x 1.45 x 0.5 Inches (BRH100-96S/53.5S))
 3-Years Product Warranty
*BRH100-96S and BRH100-24S without this function
DESCRIPTION
The BRH100 series is a new generation isolated DC-DC converter that uses
an industry standard quarter-brick structure, and features high efficiency and
power density, operates from an input voltage range of 36 V to 75 V,
provides the rated output voltage of 96V / 53.5V / 24V and the maximum output
current of 1A / 1.5A / 3A.
BRH100-96S
BRH100-53.5S
BRH100-24S
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
Regulated Voltage Precision (max.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Output
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
100% Load
(Vin = 48 V; TA=25°C (77°F))
50% Load
20% Load
Over Power Protection
Over Current Protection
Over Voltage Protection
Protection
Short Circuit Protection (max.)
Over Temperature Protection
Isolation
Environment
Safety
EMC
Physical
Other
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Tolerance 0.5 mm
Weight
Remote
Low level (V.DC.)
On/Off Voltage
High level (V.DC.)
On/Off Current
Low level (mA) (max.)
BRH100-24S
72W
48V (36~75V)
2.4A
4W
24V
3%
3A
3%
3%
BRH100-53.5S
80W
3.5A
1.25W
53.5V
1.5%
1.5A
0.5
1.5%
BRH100-96S
96W
4.0A
2.5W
96V
3%
1A
1%
1%
300 mV
200 mV
2000 mV
92.5%
92.5%
87%
89%
91%
85%
80%
86.5%
78%
Hiccup mode
Hiccup mode
26.4~33.6V
59~66V
105~115V
(Hiccup mode)
(Hiccup mode)
(Hiccup mode)
Hiccup mode
Threshold:100~130°C (typ.) / Hysteresis:5°C (min.)
Self-recovery
BRH100-96S: The values are obtained by measuring the temperature of the PCB near the thermal resistor.
others: The values are obtained by measuring the temperature of the hottest power component on the top
surface of the converter.
1500 VDC (BRH100-96S: Basic Isolation / others: Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
BRH100-24S: 2.28 x 1.45 x 0.38 Inches ( 57.9 x 36.8 x 9.7 mm )
others:.
2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm )
33 g
50 g
38 g
-0.7~1.2V
3.5~12V
1mA
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-