English
Language : 

BR400_16 Datasheet, PDF (1/3 Pages) Arch Electronics Corp. – Input under Voltage Protection
BR400 SERIES
KEY FEATURES
 Input under Voltage Protection
 Over Current Protection (Hiccup Mode)
 Short Circuit Protection (Hiccup Mode)
 Over Voltage Protection (Hiccup Mode)
 Over Temperature Protection (Self-recovery)
 Activates Hardware and Software *
 Digitally Adjusts the Voltage *
 PMBus Revision 1.1 compliant *
 Secondary ON/OFF Control *
 Pre-Bias Function *
 Peak Efficiency:96%(12V,16.5A)
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 2.28 x 1.45 x 0.5 Inches
 3-Years Product Warranty
*BR400-12S without this function
VER : A_1 update : 2015.03.16
DC-DC Brick
400 Watts
DESCRIPTION
The BR400 is an isolated DC-DC converter that uses an industry nonstandard
quarter-brick structure and features high efficiency and power density.
It provides 12 V outputs and supports the maximum output current of 33 A.
Two BR400s can be connected in parallel to provide the maximum output
current of 54 A.
The BR400 communicates over PMBus 1.1 to support monitoring and alarm
reporting functions, such as monitoring the output voltage and current, input
voltage, digitally adjusting the voltage, and activating software.
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Reflected Ripple Current (peak to peak) (typ.)
Voltage (V.DC.)
Voltage Range (V.DC.)
Output
Protection
Isolation
Environment
Safety
EMC
Physical
Voltage Trim Range (V.DC.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
Efficiency
(Vin = 48 V; TA=25°C (77°F)) (typ.)
Over Power Protection
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
BR400-12S
BR400-12S-P
396W
48V (36~72V)
14A (Vin= 36 - 72 V; Iout = 33 A)
3W (Vin= 48 V; Iout = 0 A)
200 mA (Oscilloscope Bandwidth:20 MHz)
12V
11.64~12.36V (Vin= 40 - 72 V)
11.64~12.36V
(Vin= 40 - 75 V; Adjust the voltage by PMBus)
10.8~12.36V (Vin= 36 - 40 V)
10.8~12.36V
(Vin= 36 - 40 V; Adjust the voltage by PMBus)
8.4~12V
33A
0.2% (Vin= 40 - 72 V; Iout = 33 A) / 10% (Vin= 36 - 40 V; Iout = 33 A)
3% (Vin = 48 V; Iout = 0 - 33 A)
200 mV (Oscilloscope Bandwidth:20 MHz)
100% Load:95% (Iout = 33 A)
50% Load:96% (Iout = 16.4 A)
100% Load:94% (Iout = 6.6 A)
Hiccup mode
Hiccup mode
14~16V (Hiccup mode)
Hiccup mode
Threshold:115~135°C / Hysteresis:10~20°C
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
1500 VDC (Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm ) Tolerance 0.5 mm
66 g
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-