English
Language : 

BR130_16 Datasheet, PDF (1/5 Pages) Arch Electronics Corp. – Input under Voltage Protection
BR130 SERIES
KEY FEATURES
 Input under Voltage Protection
 Over Current Protection (Hiccup Mode)
 Short Circuit Protection (Hiccup Mode)
 Over Voltage Protection (Hiccup Mode)
 Over Temperature Protection (Self-recovery)
 Remote ON/OFF Control
 Remote Sense
 Output Voltage Trim
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 2.28 x 1.45 x 0.38 Inches (others Model)
2.28 x 1.45 x 0.39 Inches (BR130-3.3S)
2.28 x 1.45 x 0.5 Inches (BR130-3.3SB)
 3-Years Product Warranty
VER : A_1 update : 2015.03.16
DC-DC Brick
36/60/72/100/132 Watts
DESCRIPTION
The BR130 series is a new generation isolated DC-DC converter that uses an
industry standard quarter-brick structure, and features high efficiency and
power density, operates from an input voltage range of 36 V to 75 V,
provides the rated output voltage of 1.2V / 1.5V / 1.8V / 2.5V / 3.3V and the
maximum output current of 30A / 40A.
BR130-1.2S / 1.5S / 1.8S / 2.5S / 3.3S
BR130-3.3SB
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Input
Voltage (V.DC.)
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
Regulated Voltage Precision (max.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Output
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
(Vin = 48 V; TA=25°C (77°F))
100% Load
50% Load
20% Load
Over Power Protection
Over Current Protection
Over Voltage Protection
Protection
Short Circuit Protection (max.)
Over Temperature Protection
Isolation
Environment
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Safety
EMC
Physical
Other
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Tolerance 0.5 mm
Weight
Remote
On/Off Voltage
On/Off Current
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
BR130- BR130-
1.2S
1.5S
36W
60W
48V (36~75V)
1.3A
2A
1W
2W
1.2V
1.5V
3%
30A
40A
0.2%
0.2%
0.2%
0.3%
BR130-
1.8S
72W
2.4A
2W
1.8V
1%
1%
BR130-
2.5S
100W
3.5A
3.5W
2.5V
0.2%
0.3%
BR130-
3.3S
132W
4.5A
3.6W
3.3V
0.2%
0.3%
BR130-
3.3SB
100 mV 100 mV 100 mV 100 mV 120 mV
89.5%
90.5%
91.5%
92%
93.5%
93.5%
89.5%
91.5%
92%
92%
93.5%
93.5%
─
87%
87%
86.5%
87.5%
─
Hiccup mode
Hiccup mode
1.4~2.0V 1.8~2.5V 2.2~3.0V 3.0~3.8V 3.9~4.7V
(Hiccup mode) (Hiccup mode) (Hiccup mode) (Hiccup mode) (Hiccup mode)
Hiccup mode
Threshold:115~135°C (typ.) / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
1500 VDC (Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
2.5
1.5
1.5
1.5
1.5
2.5
Million Hr Million Hr Million Hr Million Hr Million Hr Million Hr
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
BR130-3.3SB: 2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm )
BR130-3.3S: 2.28 x 1.45 x 0.39 Inches ( 57.9 x 36.8 x 9.8 mm )
others:
2.28 x 1.45 x 0.38 Inches ( 57.9 x 36.8 x 9.7 mm )
38 g
38 g
38 g
38 g
40 g
58 g
-0.7~1.2V
3.5~12V
1mA
http://www.archcorp.com.tw