English
Language : 

BR100 Datasheet, PDF (1/3 Pages) NXP Semiconductors – Silicon Bi-directional Trigger Device
BR100 SERIES
KEY FEATURES
 Input under Voltage Protection
 Over Current Protection (Hiccup Mode)
 Short Circuit Protection (Hiccup Mode)
 Over Voltage Protection (Hiccup Mode)
 Over Temperature Protection (Self-recovery)
 Remote ON/OFF Control
 Remote Sense *
 Output Voltage Trim *
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 1.3 x 0.9 x 0.5 Inches
 3-Years Product Warranty
*BR100-12S without this function
VER : A_1 update : 2015.03.16
DC-DC Brick
100 Watts
DESCRIPTION
The BR100 series DC-DC converter are high-efficiency and power density
standard 1/16 brick isolated models, the output power from 42W to 90W, the
output voltage covering 1.2V, 3.3V and 12V three levels. All models support
primary ON/OFF control, the 1.2V and 3.3V output models have the functions
of remote Sense and Trim. This series which conform to the RoHS6
requirement can be used in the fields of communication, data transmission and
distributed power supply system.
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
Regulated Voltage Precision (max.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Output
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
100% Load
(Vin = 48 V; TA=25°C (77°F))
50% Load
20% Load
Over Power Protection
Over Current Protection
Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
Isolation
Environment
Safety
EMC
Physical
Other
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
Remote
Low level (V.DC.)
On/Off Voltage
High level (V.DC.)
On/Off Current
Low level (mA) (max.)
BR100-1.2S
42W
48V (36~75V)
2A
1.9W
1.2V
3%
35A
0.2%
0.2%
BR100-3.3S
82.5W
3.5A
2W
3.3V
25A
0.2%
BR100-12S
90W
3.5A
2.1W
12V
7.5A
0.3%
100 mV
200 mV
200 mV
85.5%
91%
93%
88.5%
92%
93%
84.5%
89.5%
88.5%
Hiccup mode
Hiccup mode
13.8~16.2V (Hiccup mode)
Hiccup mode
Threshold: 105~130°C / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
1500 VDC (Basic Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
1.3 x 0.9 x 0.5 Inches ( 33.0 x 22.9 x 12.7 mm ) Tolerance 0.5 mm
37 g
33 g
30 g
-0.7~1.2V
3.5~12V
1mA
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-