English
Language : 

AQC100_SERIES Datasheet, PDF (1/4 Pages) Arch Electronics Corp. – High Efficiency up to 93% Typical
AQC100 SERIES
KEY FEATURES
„ Switching Power Module for PCB Mountable
„ High Efficiency up to 93% Typical
„ Active PFC Function, >0.95 (230Vac), >0.99 (115Vac)
„ Universal Input: 90-264 VAC
„ Low Leakage Current, <250uA
„ EN55022 Class B Meets
„ Class I and Class II Construction
„ Continuous Short Circuit Protection with Hiccup Mode
and Auto Recover
„ 3-Years Product Warranty
VER : A_0 update : 2010.12.17
AC-DC Power Module
100 Watts
ELECTRICAL SPECIFICATIONS
Model No.
Max Output Wattage (W)
Voltage
Frequency (Hz)
Input
Current (Full load)
Inrush Current (<2ms)
Leakage Current
Power Factor
Voltage (V.DC.)
Voltage Accuracy
Current (A) max
Line Regulation
Load Regulation
Output
Minimum Load
Maximum Capacitive Load
Ripple & Noise max.
Efficiency (typ.)
Hold-up Time
Switching Frequency
Over Power Protection
Protection
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Isolation
Input-FG (V.AC)
Output-FG .(V.AC)
Operating Temperature
Storage Temperature
Environment
Temperature Coefficient
Humidity
MTBF
Vibration
Dimension (L x W x H)
Physical
Weight
Cooling Method
Safety
Agency Approvals
EMC
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
AQC100-12S
AQC100-15S
AQC100-24S
AQC100-48S
85 W
85W
100W
100W
90-264 VAC or 120-370 VDC
47-63 Hz
<2.0 A max. (115 VAC) / <1.0 A max. (230 VAC)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
< 0.5 mA max.
PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load
12V
15V
24V
48V
±2%
7.08
5.66
4.2
2.1
±1%
±1%
0%
70,000µF
50,000µF
6,000µF
1,000µF
120mV
150mV
200mV
240mV
90%
90%
92%
93%
10 ms (110 VAC) min.
100 kHz
Auto recovery, Hiccup mode
Zener diode clamp
Auto recovery, Hiccup mode
3000V
1500V
500V
-25°C…+70°C (with derating)
-25°C…+85°C
±0.03%/°C ( 0~50°C )
95% RH
>250,000 h @ 25°C (MIL-HDBK-217F, Notice 1)
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
4.3 x 2.3 x 1.18 Inches ( 109.0 x 58.5 x 30.0 mm ) Tolerance ±0.1 mm
310 g
Free convection
CE, UL60950-1 (Pending)
EN61000-6-3、EN 55022 class B (Conductive plane to be connected to safety earth)
EN 55024、EN61000-4-2,3,4,5,6,8,11
1.All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor.
3.Hold-up Time measured at 90% Vout.