English
Language : 

AFCN Datasheet, PDF (1/2 Pages) Arch Electronics Corp. – AC-DC Power Module
AFCN SERIES
KEY FEATURES
 Switching Power Module for PCB Mountable
 Fully Encapsulated Plastic Case
 Universal Input Range 90-264VAC, 47-440 Hz
 Low Standby <0.25W
 Regulated Output and Low Ripple and Low Noise
 Isolation Class II
 Small Size: 2.07 x 1.08 x 0.93 Inches
 CE and UL Approval
 3-Year Product Warranty
VER : A_3 update : 2016.03.21
AC-DC Power Module
10 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max Output Wattage (W)
Voltage
AFCN-3.3S
AFCN-5S
8.25W
10W
90-264 VAC or 120-370 VDC
AFCN-12S
10W
AFCN-15S
10W
AFCN-24S
10W
Frequency (Hz)
47-440 Hz
Input
Current (Full load)
Inrush Current (<2ms,Cold Start)
220 mA max. (115 VAC) / 150 mA max. (230 VAC)
20 A max. (115 VAC) / 40 A max. (230 VAC)
Leakage Current
0.25 mA max.
External Fuse (mandatory)
2 A slow blow type
Voltage (V.DC.)
3.3V
5V
12V
15V
24V
Voltage Accuracy
±2%
Current (mA) max
2500
2000
833
667
417
Line Regulation (LL-HL) (typ.)
±0.5%.
Load Regulation (5-100%) (typ.)
±1%.
Output
Minimum Load
0%
Maximum Capacitive Load
8000 uF
8000 uF
2000 uF
1500 uF
560 uF
Ripple
75mV max (Vp-p)
1% of Vout
Noise
120mV max (Vp-p)
1% of Vout
Efficiency (typ.)
74%
79%
82%
78%
80%
Hold-up Time
20 ms (at 115VAC) / 80 ms (at 230VAC)
Over Power Protection
Hiccup technique, auto-recovery
Protection
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Isolation
Input-Output (V.AC)
3000V
Operating Temperature
-40°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Environment Temperature Coefficient
±0.05%/°C
Humidity
20-85% RH
MTBF
>330,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.07 x 1.08 x 0.93 Inches ( 52.5 x 27.5 x 23.5 mm ) Tolerance 0.5 mm
Physical
Case Material
Weight
Plastic resin (flammability to UL 94V-0)
58 g
Cooling Method
Free air convection
Safety
Agency Approvals
UL/cUL, CE
EMC
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 55022 class B
EN 55024
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-