English
Language : 

AEC60 Datasheet, PDF (1/2 Pages) Arch Electronics Corp. – AC-DC Medical
AEC60 SERIES
KEY FEATURES
„ Switching Power Module for PCB Mountable
„ Universal Input: 85-265 VAC
„ Single Output
„ 5 VDC to 48 VDC Output
„ -40OC Starting
„ 4000 VAC Input to Output Isolation
„ CE, UL, Approval
„ 2-Years Product Warranty
VER : A_3 update : 98.06.09
AC-DC Medical
60 Watts
ELECTRICAL SPECIFICATIONS
Model No.
Max Output Wattage (W)
Voltage
Frequency (Hz)
Input
Current (Full load)
Inrush Current (<2ms)
Leakage Current
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Load Regulation (5-100%) (typ.)
Minimum Load
Output
Maximum Capacitive Load
Ripple
Noise
Protection
Isolation
Environment
Physical
Safety
EMC
Efficiency (at 230V)
Trim
Hold-up Time
Switching Frequency
Over Power Protection
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Input-FG (V.AC)
Output-FG .(V.AC)
Operating Temperature
Storage Temperature
Temperature coefficient
Humidity
MTBF
Dimension (L x W x H)
Weight
Cooling Method
Agency Approvals
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
AEC60-5S
AEC60-9S
AEC60-12S
50W
60W
60W
85-265 VAC or 100-370 VDC
47-63 Hz
2 A max. (115 VAC) / 1 A max. (230 VAC)
AEC60-15S AEC60-24S
60W
60W
30 A max. (115 VAC) / 50 A max. (230 VAC)
0.5 mA max.
5V
9V
12V
±2%
10,000
6,660
5,000
±1%
±1%
1%
470-23,000µF depending on model
15V
4,000
24V
2,500
<0.2% Vout +40mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
82%
84%
±10%
10 ms min.
100 kHz
Auto recovery
Zener diode clamp
Auto recovery
3000V
1500V
86%
86%
86%
500V
-40°C…+70°C (with derating)
-50°C…+85°C
±0.02%/°C
95% RH
>130,000 h @ 25°C (MIL-HDBK-217F)
4.3 x 2.3 x 1.18 Inches ( 109.0 x 58.5 x 30 mm ) Tolerance ±0.5 mm
310 g
Free air convection
CE, UL60950
AEC60-48S
60W
48V
1,250
86%
EN 55022 class B
EN 55024
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-